ATM90E26-YU-B

Atmel M90E26

Manufacturer

unknown

Overview

Part: Atmel M90E26

Type: Single-Phase High-Performance Wide-Span Energy Metering IC

Key Specs:

  • Active energy accuracy: 0.1% over 5000:1 dynamic range
  • Reactive energy accuracy: 0.2% over 5000:1 dynamic range
  • Temperature coefficient (on-chip reference): 15 ppm/°C (typical)
  • Single power supply: 3.3V
  • Operating voltage range: 2.8V~3.6V
  • Metering accuracy guaranteed voltage range: 3.0V~3.6V
  • Operating temperature: -40 °C ~ +85 °C
  • Crystal oscillator frequency: 8.192 MHz
  • Voltage channel input range (gain '1'): 120μVrms~600mVrms
  • L line current channel input range (gain '24'): 5μVrms~25mVrms
  • N line current channel input range (gain '1'): 120μVrms~600mVrms

Features:

  • Compliance with IEC62052-11, IEC62053-21, IEC62053-23
  • Single-point calibration for active energy
  • Energy Meter Constant doubling at low current
  • Electrical parameters measurement (Vrms, Irms, mean active/reactive/apparent power, frequency, power factor, phase angle) with less than ±0.5% fiducial error
  • Forward/reverse active/reactive energy with independent energy registers
  • Programmable startup and no-load power threshold
  • Dedicated ADC and different gains for L line and N line current sampling
  • Current sampled over shunt resistor or current transformer (CT); voltage sampled over resistor divider network or potential transformer (PT)
  • Programmable L line and N line metering modes: anti-tampering, L line, L+N, flexible
  • Programmable L line and N line power difference threshold in anti-tampering mode
  • 5V compatible for digital input
  • Built-in hysteresis for power-on reset
  • Selectable UART interface and SPI interface (four-wire or simplified three-wire)
  • Parameter diagnosis function and programmable interrupt output (IRQ, WarnOut)
  • Programmable voltage sag detection and zero-crossing output
  • Programmable L line current gain: 1, 4, 8, 16, 24
  • Programmable N line gain: 1, 2, 4
  • Support L line and N line offset compensation
  • CF1 and CF2 output active and reactive energy pulses

Applications:

  • Active and reactive energy metering for single-phase two-wire (1P2W) systems
  • Active and reactive energy metering for single-phase three-wire (1P3W) systems
  • Active and reactive energy metering for anti-tampering energy meters
  • Power instruments requiring voltage, current measurement

Package:

  • SSOP28: null

Features

  • Metering features fully in compliance with the requirements of IEC62052-11, IEC62053-21 and IEC62053-23; applicable in class 1 or class 2 single-phase watthour meter or class 2 single-phase var-hour meter.
  • Accuracy of 0.1% for active energy and 0.2% for reactive energy over a dynamic range of 5000:1.
  • Temperature coefficient is 15 ppm/ °C (typical) for on-chip reference voltage
  • Single-point calibration over a dynamic range of 5000:1 for active energy; no calibration needed for reactive energy.
  • Energy Meter Constant doubling at low current to save verification time.
  • Electrical parameters measurement: less than ±0.5% fiducial error for Vrms, Irms, mean active/ reactive/ apparent power, frequency, power factor and phase angle.
  • Forward/ reverse active/ reactive energy with independent energy registers. Active/ reactive energy can be output by pulse or read through energy registers to adapt to different applications.
  • Programmable startup and no-load power threshold.
  • Dedicated ADC and different gains for L line and N line current sampling circuits. Current sampled over shunt resistor or current transformer (CT); voltage sampled over resistor divider network or potential transformer (PT).
  • Programmable L line and N line metering modes: anti-tampering mode (larger power), L line mode (fixed L line), L+N mode (applicable for single-phase three-wire system) and flexible mode (configure through register).
  • Programmable L line and N line power difference threshold in anti-tampering mode.

Pin Configuration

Figure-2 Pin Assignment (Top View)

Absolute Maximum Ratings

ParameterMaximum Limit
Relative Voltage Between AVDD and AGND-0.3V~3.7V
Relative Voltage Between DVDD and DGND-0.3V~3.7V
Analog Input Voltage (I1P, I1N, I2P, I2N, VP, VN)-1V~VDD
Digital Input Voltage-0.3V~VDD+2.6V
Operating Temperature Range-40~85 °C
Maximum Junction Temperature150 °C
Package TypeThermal Resistance θJAUnitCondition
Green SSOP2849°C/WNo Airflow

Related Variants

The following components are covered by the same datasheet.

Part NumberManufacturerPackage
ATM90E26unknown
ATM90E26-YU-Runknown
Data on this page is extracted from publicly available manufacturer datasheets using automated tools including AI. It may contain errors or omissions. Always verify specifications against the official manufacturer datasheet before making design or purchasing decisions. See our Terms of Service. Rights holders can submit a takedown request.

Get structured datasheet data via API