ATM90E26 Key Specifications

ParameterValue
Digital Input5V compatible
Dynamic Range5000:1
Supply Voltage3.3V nominal (2.8V to 3.6V operating)
L Line Current Gain1, 4, 8, 16, 24
N Line Current Gain1, 2, 4
Operating Temperature-40 °C to +85 °C
Active Energy Accuracy0.1%
Thermal Resistance θJA49 °C/W (no airflow)
Communication InterfacesUART, SPI (4-wire or simplified 3-wire)
Reactive Energy Accuracy0.2%
Measurement Fiducial Errorless than ±0.5%
Voltage Channel Input Range120 μVrms to 600 mVrms (gain 1)
Crystal Oscillator Frequency8.192 MHz
Maximum Junction Temperature150 °C
Metering Accuracy Supply Range3.0V to 3.6V
L Line Current Channel Input Range5 μVrms to 25 mVrms (gain 24)
Reference Voltage Temp Coefficient15 ppm/°C (typical)

ATM90E26 Overview

Part: M90E26

Type: Single-Phase High-Performance Wide-Span Energy Metering IC

Description: Single-phase energy metering IC with 0.1% active energy accuracy over a 5000:1 dynamic range, operating from a 2.8–3.6 V supply with SPI and UART interfaces.

Operating Conditions:

  • Supply voltage: 2.8–3.6 V (3.0–3.6 V for guaranteed metering accuracy)
  • Operating temperature: -40 to +85 °C
  • Crystal oscillator frequency: 8.192 MHz

Absolute Maximum Ratings:

  • Max supply voltage: 3.7 V (Relative Voltage Between AVDD and AGND, DVDD and DGND: -0.3 V to 3.7 V)
  • Max junction/storage temperature: 150 °C (Maximum Junction Temperature)

Key Specs:

  • Active energy metering accuracy: 0.1% over a 5000:1 dynamic range
  • Reactive energy metering accuracy: 0.2% over a 5000:1 dynamic range
  • Reference voltage temperature coefficient: 15 ppm/°C (typical)
  • Electrical parameters measurement error: < ±0.5% fiducial error for Vrms, Irms, power, frequency, power factor, phase angle
  • L line current channel input range (gain = 24): 5 μVrms to 25 mVrms
  • Voltage channel input range (gain = 1): 120 μVrms to 600 mVrms
  • N line current channel input range (gain = 1): 120 μVrms to 600 mVrms
  • Programmable current amplifier gains: 1, 4, 8, 16, 24 (L line); 1, 2, 4 (N line)

Features:

  • Compliance with IEC62052-11, IEC62053-21, and IEC62053-23 for Class 1 and Class 2 meters
  • Selectable 4-wire SPI, 3-wire SPI, or UART interfaces
  • Dedicated ADCs with programmable gains for L line and N line current sampling
  • Anti-tampering, fixed L line, and L+N (single-phase three-wire) metering modes
  • CF1 and CF2 outputs for active and reactive energy pulses
  • Programmable voltage sag detection and zero-crossing output
  • Single-point calibration for active energy; no calibration required for reactive energy

Applications:

  • Single-phase two-wire (1P2W) active and reactive energy meters
  • Single-phase three-wire (1P3W) energy meters
  • Anti-tampering energy meters
  • Power instruments requiring voltage and current measurement

Package:

  • Green SSOP28

ATM90E26 Features

  • Metering features fully in compliance with the requirements of IEC62052-11, IEC62053-21 and IEC62053-23; applicable in class 1 or class 2 single-phase watthour meter or class 2 single-phase var-hour meter.
  • Accuracy of 0.1% for active energy and 0.2% for reactive energy over a dynamic range of 5000:1.
  • Temperature coefficient is 15 ppm/ °C (typical) for on-chip reference voltage
  • Single-point calibration over a dynamic range of 5000:1 for active energy; no calibration needed for reactive energy.
  • Energy Meter Constant doubling at low current to save verification time.
  • Electrical parameters measurement: less than ± 0.5% fiducial error for Vrms, Irms, mean active/ reactive/ apparent power, frequency, power factor and phase angle.
  • Forward/ reverse active/ reactive energy with independent energy registers. Active/ reactive energy can be output by pulse or read through energy registers to adapt to different applications.
  • Programmable startup and no-load power threshold.
  • Dedicated ADC and different gains for L line and N line current sampling circuits. Current sampled over shunt resistor or current transformer (CT); voltage sampled over resistor divider network or potential transformer (PT).
  • Programmable L line and N line metering modes: anti-tampering mode (larger power), L line mode (fixed L line), L+N mode (applicable for single-phase three-wire system) and flexible mode (configure through register).
  • Programmable L line and N line power difference threshold in anti-tampering mode.

ATM90E26 Pin Configuration

Figure-2 Pin Assignment (Top View)

ATM90E26 Absolute Maximum Ratings

ParameterMaximum Limit
Relative Voltage Between AVDD and AGND-0.3V~3.7V
Relative Voltage Between DVDD and DGND-0.3V~3.7V
Analog Input Voltage (I1P, I1N, I2P, I2N, VP, VN)-1V~VDD
Digital Input Voltage-0.3V~VDD+2.6V
Operating Temperature Range-40~85 °C
Maximum Junction Temperature150 °C
Package TypeThermal Resistance θ JAUnitCondition
Green SSOP2849°C/WNo Airflow

Variants on the same datasheet

These parts have exact links to the same datasheet. They are candidates to compare, not verified drop-in replacements; check package, pinout and electrical limits.

Part NumberManufacturerPackage
ATM90E26-YU-BMicrochip TechnologySSOP-28
ATM90E26-YU-RMicrochip TechnologySSOP28

Other Integrated Circuits

All Integrated Circuits datasheetsAll Microchip Technology datasheets (600)

Data on this page is extracted from publicly available manufacturer datasheets using automated tools including AI. It may contain errors or omissions. Always verify specifications against the official manufacturer datasheet before making design or purchasing decisions. See our Terms of Service. Rights holders can submit a takedown request.

Ask your AI agent about the ATM90E26

Connect SheetsData to Claude, Cursor, Codex or any MCP client and your agent reads this datasheet for you: pinout, limits, register maps and design checks, with the numbers taken from the PDF.

claude mcp add --transport http sheetsdata https://mcp.sheetsdata.com/mcp

Then ask: "Can the ATM90E26 run from my 12 V rail? Check it against the datasheet limits."

Create a free account $2 of usage every month, no card needed.