Skip to main content

We use cookies to understand how you use our site and improve your experience. See our Privacy Policy.

TMP117NAIDRVR

Digital Temperature Sensor

The TMP117NAIDRVR is a digital temperature sensor from Texas Instruments. View the full TMP117NAIDRVR datasheet below including key specifications, electrical characteristics, absolute maximum ratings.

TMP117NAIDRVR shares its datasheet with TMP117N, whose page lists every part number it covers.

Official TMP117NAIDRVR datasheet (PDF) — the source this page was extracted from.

Manufacturer

Texas Instruments

Package

6-WDFN Exposed Pad

Lifecycle

Active

TMP117NAIDRVR Key Specifications

ParameterValue
Accuracy (Sensor)±0.2°C (±0.3°C)
FeaturesStandby Mode, Shutdown Mode, One-Shot, Programmable Limit
Mounting TypeSurface Mount
Operating Temperature-55°C ~ 150°C (TA)
Output TypeI2C/SMBus
Package / Case6-WDFN Exposed Pad
Resolution16 b
Sensing Temperature Range-55°C ~ 150°C
Sensor TypeDigital, Local
Supplier Device Package6-WSON (2x2)
Test Condition-40°C ~ 100°C (-55°C ~ 150°C)
Supply Voltage1.8V ~ 5.5V

TMP117NAIDRVR Overview

Part: TMP117 (TMP117NAIDRVR) — Texas Instruments

Type: High-Accuracy Digital Temperature Sensor (SMBus/I²C)

Description: 1.7–5.5 V, 16-bit (0.0078 °C/LSB) digital temperature sensor with ±0.1 °C maximum accuracy from -20 °C to 50 °C, 3.5 μA typical consumption at a 1-Hz conversion cycle, and an I²C/SMBus-compatible interface.

Operating Conditions:

  • Supply voltage: 1.8–5.5 V for TA = -55 °C to 150 °C; 1.7–5.5 V for TA = -55 °C to 70 °C
  • Operating temperature: -55 to 150 °C
  • SCL, SDA, ALERT and ADD0 voltage: 0–5.5 V

Absolute Maximum Ratings:

  • Max supply voltage: 6 V
  • Voltage at SCL, SDA, ALERT and ADD0: -0.3 to 6 V
  • Max operating junction temperature: 155 °C
  • Storage temperature: -65 to 155 °C

Key Specs:

  • Accuracy (max): ±0.1 °C (-20 to 50 °C), ±0.15 °C (-40 to 70 °C), ±0.2 °C (-40 to 100 °C), ±0.25 °C (-55 to 125 °C), ±0.3 °C (-55 to 150 °C)
  • Resolution: 16-bit, 0.0078 °C (1 LSB)
  • Supply current: 3.5 μA typical at 1-Hz conversion cycle
  • Shutdown current: 150 nA
  • Interface: SMBus and I²C compatible; up to four devices on a single bus
  • Memory: 48-bit general-purpose EEPROM

Features:

  • Programmable temperature alert limits
  • Selectable averaging
  • Digital offset for system correction
  • NIST traceable; 100% production tested on ISO/IEC 17025-calibrated equipment
  • Medical grade: meets ASTM E1112 and ISO 80601-2-56
  • Replacement for PT100, PT500 and PT1000 RTDs

Applications:

  • Electronic thermometers
  • Wireless environmental sensors
  • Thermostats
  • Automotive test equipment
  • Wearable fitness and activity monitors
  • Cold chain asset tracking
  • Gas meters and heat meters
  • Temperature transmitters

Package:

  • WSON (6), 2.00 mm × 2.00 mm
  • DSBGA (6), 1.53 mm × 1.00 mm

TMP117NAIDRVR Features

  • TMP117 high-accuracy temperature sensor
  • -±0.1 °C (maximum) from -20 °C to 50 °C
  • -±0.15 °C (maximum) from -40 °C to 70 °C
  • -±0.2 °C (maximum) from -40 °C to 100 °C
  • -±0.25 °C (maximum) from -55 °C to 125 °C
  • -±0.3 °C (maximum) from -55 °C to 150 °C
  • Operating temperature range: -55 °C to 150 °C
  • Low power consumption:
  • -3.5-μA, 1-Hz conversion cycle
  • -150-nA shutdown current
  • Supply range:
  • -1.7 V to 5.5 V from -55 °C to 70 °C
  • -1.8 V to 5.5 V from -55 °C to 150 °C
  • 16-bit resolution: 0.0078°C (1 LSB)
  • Programmable temperature alert limits
  • Selectable averaging
  • Digital offset for system correction
  • General-purpose EEPROM: 48 bits
  • NIST traceability
  • SMBus ™ , I 2 C interface compatibility
  • Medical grade: meets ASTM E1112 and ISO 80601-2-56
  • RTDs replacement: PT100, PT500, PT1000

TMP117NAIDRVR Applications

  • Electronic thermometers
  • Wireless environmental sensors
  • Thermostats
  • Automotive test equipment
  • Wearable fitness and activity monitors
  • Cold chain asset tracking
  • Gas meters and heat meters
  • Temperature transmitters

Accu TMP117

YBG Temperature Accuracy

SNOSD82D - JUNE 2018 - REVISED SEPTEMBER 2022

TMP117NAIDRVR Pin Configuration

Figure 5-1. DRV Package 6-Pin WSON Top View

A

B

C

Figure 5-2. YBG Package 6-Pin DSBGA Top View

TMP117NAIDRVR Electrical Characteristics

Over free-air temperature range and V+ = 1.7 V to 5.5 V for T A = -55 °C to 70 °C, or V+ = 1.8 V to 5.5 V for T A = -55 °C to 150 °C (unless otherwise noted); Typical specifications are at T A = 25 °C and V+ = 3.3 V (unless otherwise noted)

PARAMETERPARAMETERTEST CONDITIONSTEST CONDITIONSMINTYPMAXUNIT
TEMPERATURE TO DIGITAL CONVERTERTEMPERATURE TO DIGITAL CONVERTERTEMPERATURE TO DIGITAL CONVERTERTEMPERATURE TO DIGITAL CONVERTERTEMPERATURE TO DIGITAL CONVERTERTEMPERATURE TO DIGITAL CONVERTERTEMPERATURE TO DIGITAL CONVERTERTEMPERATURE TO DIGITAL CONVERTERTEMPERATURE TO DIGITAL CONVERTER
TMP117-20 °C to 50 °C-0.1±0.050.1°C
TMP117-40 °C to 70 °C-0.15±0.050.15°C
TMP117-40 °C to 100 °C-0.2±0.10.2°C
TMP117-55 °C to 125 °C-0.25±0.10.25°C
TMP117-55 °C to 150 °C1-Hz conversion cycle Thermal Pad unsoldered (DRV Package) I 2 C Input voltages: V IL ≤-0.3±0.10.3°C
25 °C to 50 °C1-Hz conversion cycle Thermal Pad unsoldered (DRV Package) I 2 C Input voltages: V IL ≤-0.1±0.050.1°C
0°C to 70 °C1-Hz conversion cycle Thermal Pad unsoldered (DRV Package) I 2 C Input voltages: V IL ≤-0.15±0.050.15°C
0 °C to 85 °C1-Hz conversion cycle Thermal Pad unsoldered (DRV Package) I 2 C Input voltages: V IL ≤-0.2±0.10.2°C
-40 °C to 100 °C1-Hz conversion cycle Thermal Pad unsoldered (DRV Package) I 2 C Input voltages: V IL ≤-0.2±0.10.2°C
-55 °C to 125 °C1-Hz conversion cycle Thermal Pad unsoldered (DRV Package) I 2 C Input voltages: V IL ≤-0.25±0.10.25°C
-55 °C to 150 °C1-Hz conversion cycle Thermal Pad unsoldered (DRV Package) I 2 C Input voltages: V IL ≤-0.3±0.10.3°C
DC power supply sensitivityDC power supply sensitivityDC power supply sensitivityOne-shot mode, 8 AveragesOne-shot mode, 8 Averages6m°C/V
Temperature resolution (LSB)Temperature resolution (LSB)Temperature resolution (LSB)7.8125m°C
Repeatability (1)Repeatability (1)Repeatability (1)V+ = 3.3 V 8 averages 1-Hz conversion cycleV+ = 3.3 V 8 averages 1-Hz conversion cycle±1LSB
Long-term stability and driftLong-term stability and driftLong-term stability and drift1000 hours at 150 °C (2)1000 hours at 150 °C (2)±0.03°C
Temperature cycling and hysteresis (3)Temperature cycling and hysteresis (3)Temperature cycling and hysteresis (3)8 Averages8 Averages±2LSB
Conversion timeConversion timeConversion timeOne-shot modeOne-shot mode1315.517.5ms
DIGITAL INPUT/OUTPUTDIGITAL INPUT/OUTPUTDIGITAL INPUT/OUTPUTDIGITAL INPUT/OUTPUTDIGITAL INPUT/OUTPUTDIGITAL INPUT/OUTPUTDIGITAL INPUT/OUTPUT
4
DIGITAL INPUT/OUTPUTDIGITAL INPUT/OUTPUT
pF
Input capacitance V IHInput capacitance V IHInput capacitance V IHSCL, SDASCL, SDA0.7 * (V+)V
V IL Input logic low levelV IL Input logic low levelV IL Input logic low levelSCL, SDASCL, SDA* (V+)V
I IN Input leakage currentI IN Input leakage currentI IN Input leakage current-0.10.1μA
V OL SDA and ALERT output logic low levelV OL SDA and ALERT output logic low levelV OL SDA and ALERT output logic low levelI OL = -3 mAI OL = -3 mA00.4V
POWER SUPPLYPOWER SUPPLYPOWER SUPPLYPOWER SUPPLYPOWER SUPPLYPOWER SUPPLYPOWER SUPPLYPOWER SUPPLYPOWER SUPPLY
I Q_ACTIV E Quiescent current during active conversionI Q_ACTIV E Quiescent current during active conversionI Q_ACTIV E Quiescent current during active conversionActive Conversion, serial bus inactiveActive Conversion, serial bus inactive135220μA
I QDuty cycle 1 Hz, averaging mode off, serial bus inactive. T A = 25 °CDuty cycle 1 Hz, averaging mode off, serial bus inactive. T A = 25 °C3.55
Quiescent currentQuiescent currentDuty cycle 1 Hz, 8 averaging mode on, serial bus inactive. T A = 25 °C
Duty cycle 1 Hz, averaging mode off, serial bus active, SCL frequency = 400 kHz
Duty cycle 1 Hz, 8 averaging mode on, serial bus inactive. T A = 25 °C
Duty cycle 1 Hz, averaging mode off, serial bus active, SCL frequency = 400 kHz
16
15
22μA
I SBStandby current (4)Standby current (4)Serial bus inactive. SCL, SDA, and ADD0 = V+. T A = 25 °CSerial bus inactive. SCL, SDA, and ADD0 = V+. T A = 25 °C1.253.1μA
Shutdown currentShutdown currentSerial bus inactive, SCL, SDA, and ADD0 = V+. T A = 25 °CSerial bus inactive, SCL, SDA, and ADD0 = V+. T A = 25 °C0.150.5μA
I SDShutdown currentShutdown currentSerial bus inactive, SCL, SDA and ADD0 = V+, T A = 150 °CSerial bus inactive, SCL, SDA and ADD0 = V+, T A = 150 °C5μA
I SDShutdown currentShutdown currentSerial bus active, SCL frequency = 400 kHz, ADD0 = V+Serial bus active, SCL frequency = 400 kHz, ADD0 = V+17μA
I EEEEPROM write quiescent currentEEPROM write quiescent currentADC conversion off; serial bus inactiveADC conversion off; serial bus inactive240μA

Over free-air temperature range and V+ = 1.7 V to 5.5 V for T A = -55 °C to 70 °C, or V+ = 1.8 V to 5.5 V for T A = -55 °C to 150 °C (unless otherwise noted); Typical specifications are at T A = 25 °C and V+ = 3.3 V (unless otherwise noted)

PARAMETERPARAMETERTEST CONDITIONSTYPUNIT
V PORPower-on-reset threshold voltageSupply rising1.6V
Brownout detectSupply falling1.1V
t RESETReset TimeTime required by device to reset1.5ms

TMP117NAIDRVR Absolute Maximum Ratings

Over free-air temperature range unless otherwise noted (1)

MINMAXUNIT
Supply voltageV+-0.36V
Voltage atSCL, SDA, ALERT and ADD0-0.36V
Operating junction temperature, T JOperating junction temperature, T J-55155°C
Storage temperature, T stgStorage temperature, T stg-65155°C
MINNOMMAXUNIT
V+Supply voltage, T A = -55 °C to 150 °C1.83.35.5V
V+Supply voltage, T A = -55 °C to 70 °C1.75.5V
V I/OSCL, SDA, ALERT and ADD005.5V
T AOperating free-air temperature-55150°C

TMP117NAIDRVR Thermal Information

THERMAL METRIC (1)TMP117 - YBG (DSBGA) - 6 PINSTMP117 - DRV (WSON) - 6 PINSUNIT
R θJAJunction-to-ambient thermal resistance133.270.7°C/W
R θJC(top)Junction-to-case (top) thermal resistance1.082.3°C/W
R θJC(bot)Junction-to-case (bottom) thermal resistanceN/A11.7°C/W
R θJBJunction-to-board thermal resistance40.935.4°C/W
ψ JTJunction-to-top characterization parameter0.12.2°C/W
ψ JBJunction-to-board characterization parameter40.735.3°C/W
M TThermal Mass0.85.1mJ/°C

TMP117NAIDRVR Typical Application

The TMP117 is used to measure the temperature of the board location where the device is mounted. The programmable address options allow up to four locations on the board to be monitored on a single serial bus. For more information, refer to the related Considerations for Measuring Ambient Air Temperature (SNOA966), Replacing resistance temperature detectors with the TMP116 temp sensor (SNOA969), and Temperature sensors: PCB guidelines for surface mount devices (SNOA967) application reports on ti.com.

Variants on the same datasheet

These parts have exact links to the same datasheet. They are candidates to compare, not verified drop-in replacements; check package, pinout and electrical limits.

Part NumberManufacturerPackage
TMP117Texas Instruments—
TMP117NTexas Instruments—

Other Temperature Sensors

  • BME280 – Bosch Sensortec, Digital Humidity, Pressure, and Temperature Sensor
  • SHT30 – Sensirion, Humidity and Temperature Sensor
  • Si7021 – Silicon Labs, I2C Humidity and Temperature Sensor
  • SHT31-DIS-B2.5kS – Sensirion, Digital Humidity and Temperature Sensor
  • TMP116NAIDRVR – Texas Instruments, Digital Temperature Sensor
  • BME280.C – Bosch Sensortec, Digital Humidity, Pressure, and Temperature Sensor
  • BME280.H – Bosch Sensortec, Digital Humidity, Pressure, and Temperature Sensor
  • DS18B20 – Analog Devices, Digital Thermometer

All Temperature Sensors datasheetsAll Texas Instruments datasheets (2,442)

Data on this page is extracted from publicly available manufacturer datasheets using automated tools including AI. It may contain errors or omissions. Always verify specifications against the official manufacturer datasheet before making design or purchasing decisions. See our Terms of Service. Rights holders can submit a takedown request.

Ask your AI agent about the TMP117NAIDRVR