SI7021-A10-GMR
I2C Humidity and Temperature SensorThe SI7021-A10-GMR is a i2c humidity and temperature sensor from Silicon Labs. View the full SI7021-A10-GMR datasheet below including key specifications, electrical characteristics, absolute maximum ratings.
SI7021-A10-GMR shares its datasheet with Si7021, whose page lists every part number it covers.
Official SI7021-A10-GMR datasheet (PDF) — the source this page was extracted from.
Manufacturer
Silicon LabsCategory
Temperature SensorsSI7021-A10-GMR Key Specifications
| Parameter | Value |
|---|---|
| RH accuracy | ±3% RH (max), 0-80% RH |
| Temperature accuracy | ±0.4 °C (max), -10 to 85 °C |
| Active current (RH conversion) | 150 μA (typ) |
| Active current (Temperature conversion) | 90 μA (typ) |
| Standby current | 60 nA (typ), -40 to +85 °C |
| RH conversion time (12-bit) | 10 ms (typ) |
| Temperature conversion time (14-bit) | 7 ms (typ) |
| I2C SCLK frequency | 400 kHz (max) |
SI7021-A10-GMR Overview
Part: Si7021-A10 — Silicon Labs
Type: I2C Humidity and Temperature Sensor
Description: The Si7021 is a monolithic CMOS IC integrating humidity and temperature sensor elements, an analog-to-digital converter, signal processing, calibration data, and an I2C Interface, offering ±3% RH (max) accuracy from 0-80% RH and ±0.4 °C (max) accuracy from -10 to 85 °C.
Operating Conditions:
- Supply voltage: 1.9–3.6 V
- Operating temperature: -40 to +125 °C (I and Y grade), -40 to +85 °C (G grade)
- Operating humidity range: 0 to 100% RH (non-condensing)
Absolute Maximum Ratings:
- Max supply voltage: 4.2 V
- Max junction/storage temperature: 150 °C
- Max ambient temperature under bias: 125 °C
Key Specs:
- RH accuracy: ±3% RH (max), 0-80% RH
- Temperature accuracy: ±0.4 °C (max), -10 to 85 °C
- Active current (RH conversion): 150 μA (typ)
- Active current (Temperature conversion): 90 μA (typ)
- Standby current: 60 nA (typ), -40 to +85 °C
- RH conversion time (12-bit): 10 ms (typ)
- Temperature conversion time (14-bit): 7 ms (typ)
- I2C SCLK frequency: 400 kHz (max)
Features:
- Precision Relative Humidity Sensor
- High Accuracy Temperature Sensor
- Low Power Consumption
- Factory-calibrated
- I2C Interface
- Integrated on-chip heater
- Excellent long term stability
- Optional factory-installed cover
Applications:
- HVAC/R
- Thermostats/humidistats
- Respiratory therapy
- White goods
- Indoor weather stations
- Micro-environments/data centers
- Automotive climate control and defogging
- Asset and goods tracking
- Mobile phones and tablets
Package:
- 3x3 mm DFN
- 3x3 mm 6-pin DFN with Protective Cover
SI7021-A10-GMR Features
- Precision Relative Humidity Sensor
- ± 3% RH (max), 0-80% RH
- High Accuracy Temperature Sensor ±0.4 °C (max), -10 to 85 °C
- 0 to 100% RH operating range
- Up to -40 to +125 °C operating range
- Wide operating voltage (1.9 to 3.6 V)
- Low Power Consumption
- 150 μA active current
- 60 nA standby current
SI7021-A10-GMR Applications
- HVAC/R
- Thermostats/humidistats
- Respiratory therapy
- White goods
- Indoor weather stations
SI7021-A10-GMR Pin Configuration
| Pin Name | Pin # | Pin Description |
|---|---|---|
| SDA | 1 | I 2 C data |
| GND | 2 | Ground. This pin is connected to ground on the circuit board through a trace. Do not connect directly to GND plane. |
| VDD | 5 | Power. This pin is connected to power on the circuit board. |
| SCL | 6 | I 2 C clock |
| DNC | 3,4 | These pins should be soldered to pads on the PCB for mechanical stability; they can be electrically floating or tied to VDD (do not tie to GND). |
| T GND | Paddle | This pad is connected to GND internally. This pad is the main thermal input to the on- chip temperature sensor . The paddle should be soldered to a floating pad. |
SI7021-A10-GMR Electrical Characteristics
Unless otherwise specified, all min/max specifications apply over the recommended operating conditions.
Table 1. Recommended Operating Conditions
| Parameter | Symbol | Test Condition | Min | Typ | Max | Unit |
|---|---|---|---|---|---|---|
| Power Supply | VDD | 1.9 | 3.6 | V | ||
| Operating Temperature | TA | I and Y grade | -40 | - | 125 | °C |
| Operating Temperature | TA | G grade | -40 | - | 85 | °C |
SI7021-A10-GMR Absolute Maximum Ratings
| Parameter | Symbol | Test Condition | Min | Typ | Max | Unit |
|---|---|---|---|---|---|---|
| Ambient temperature under bias | -55 | - | 125 | °C | ||
| Storage Temperature 2 | -65 | - | 150 | °C | ||
| Voltage on I/O pins | -0.3 | - | VDD+0.3V | V | ||
| Voltage on VDD with respect to GND | -0.3 | 4.2 | V | |||
| ESD Tolerance | HBM | - | - | 2 | kV | |
| ESD Tolerance | CDM | - | - | 1.25 | kV | |
| ESD Tolerance | MM | - | - | 250 | V |
-
Absolute maximum ratings are stress ratings only, operation at or beyond these conditions is not implied and may shorten the life of the device or alter its performance.
-
Special handling considerations apply; see application note, 'AN607: Si70xx Humidity Sensor Designer's Guide'.
SI7021-A10-GMR Thermal Information
| Parameter | Symbol | Test Condition | DFN-6 | Unit |
|---|---|---|---|---|
| Junction to Air Thermal Resistance | JA | JEDEC 2-Layer board, No Airflow | 256 | °C/W |
| Junction to Air Thermal Resistance | JA | JEDEC 2-Layer board, 1 m/s Airflow | 224 | °C/W |
| Junction to Air Thermal Resistance | JA | JEDEC 2-Layer board, 2.5 m/s Airflow | 205 | °C/W |
| Junction to Case Thermal Resistance | JC | JEDEC 2-Layer board | 22 | °C/W |
| Junction to Board Thermal Resistance | JB | JEDEC 2-Layer board | 134 | °C/W |
SI7021-A10-GMR Typical Application
The primary function of the Si7021 is to measure relative humidity and temperature. Figure 4 demonstrates the typical application circuit to achieve these functions.
Figure 4. Typical Application Circuit for Relative Humidity and Temperature Measurement
Figure 4. Typical Application Circuit for Relative Humidity and Temperature Measurement
SI7021-A10-GMR Package Information
Figure 10. 3x3 6-pin DFN
Table 14. 3x3 6-pin DFN Package Diagram Dimensions
| Dimension | Min | Nom | Max |
|---|---|---|---|
| A | 0.70 | 0.75 | 0.80 |
| A1 | 0.00 | 0.02 | 0.05 |
| b | 0.35 | 0.40 | 0.45 |
| D | 3.00 BSC. | 3.00 BSC. | 3.00 BSC. |
| D2 | 1.40 | 1.50 | 1.60 |
| e | 1.00 BSC. | 1.00 BSC. | 1.00 BSC. |
| E | 3.00 BSC. | 3.00 BSC. | 3.00 BSC. |
| E2 | 2.30 | 2.40 | 2.50 |
| H1 | 0.85 | 0.90 | 0.95 |
| H2 | 1.39 | 1.44 | 1.49 |
| L | 0.35 | 0.40 | 0.45 |
| aaa | 0.10 | 0.10 | 0.10 |
| bbb | 0.10 | 0.10 | 0.10 |
| ccc | 0.05 | 0.05 | 0.05 |
| ddd | 0.10 | 0.10 | 0.10 |
| eee | 0.05 | 0.05 | 0.05 |
| fff | 0.05 | 0.05 | 0.05 |
- All dimensions shown are in millimeters (mm).
- Dimensioning and Tolerancing per ANSI Y14.5M-1994.
Other Temperature Sensors
- BME280 – Bosch Sensortec, Digital Humidity, Pressure, and Temperature Sensor
- SHT30 – Sensirion, Humidity and Temperature Sensor
- Si7021 – Silicon Labs, I2C Humidity and Temperature Sensor
- SHT31-DIS-B2.5kS – Sensirion, Digital Humidity and Temperature Sensor
- TMP116NAIDRVR – Texas Instruments, Digital Temperature Sensor
- BME280.C – Bosch Sensortec, Digital Humidity, Pressure, and Temperature Sensor
- BME280.H – Bosch Sensortec, Digital Humidity, Pressure, and Temperature Sensor
- DS18B20 – Analog Devices, Digital Thermometer
All Temperature Sensors datasheetsAll Silicon Labs datasheets (179)
Ask your AI agent about the SI7021-A10-GMR
Connect SheetsData to Claude, Cursor, Codex or any MCP client and your agent reads this datasheet for you: pinout, limits, register maps and design checks, with the numbers taken from the PDF.
claude mcp add --transport http sheetsdata https://mcp.sheetsdata.com/mcp
Then ask: "Can the SI7021-A10-GMR run from my 12 V rail? Check it against the datasheet limits."
Create a free account $2 of usage every month, no card needed.