SCD40-D-R2
CO2, Humidity, and Temperature SensorThe SCD40-D-R2 is a co2, humidity, and temperature sensor from Sensirion. View the full SCD40-D-R2 datasheet below including key specifications, electrical characteristics, absolute maximum ratings.
SCD40-D-R2 shares its datasheet with SCD40, whose page lists every part number it covers.
Official SCD40-D-R2 datasheet (PDF) — the source this page was extracted from.
SCD40-D-R2 Key Specifications
| Parameter | Value |
|---|---|
| Accuracy | ±5% |
| Operating Temperature | -10°C ~ 60°C |
| Output | I2C |
| Packaging | Cut Tape |
| Standard Pack Qty | 600 |
| Type | Carbon Dioxide (CO2), Humidity, Temperature |
| Supply Voltage | 2.4V ~ 5.5V |
SCD40-D-R2 Overview
Part: SCD40 (SCD4x family, SCD40-D-R2) — Sensirion
Type: Photoacoustic NDIR CO2 Sensor with integrated temperature and humidity sensor
Description: Miniature 10.1 x 10.1 x 6.5 mm photoacoustic NDIR CO2 sensor with I²C interface, 2.4–5.5 V supply, specified 400–2,000 ppm range at ±(50 ppm + 5% of reading) accuracy (SCD40).
Operating Conditions:
- Supply voltage: 2.4–5.5 V (3.3 V or 5.0 V typical)
- Operating temperature: -10 to 60 °C
- Humidity: 0–95 %RH, non-condensing
- I²C SCL clock up to 400 kHz
Absolute Maximum Ratings:
- Max supply voltage: 6.0 V (min -0.3 V)
- Max voltage on SDA, SCL, GND: VDD + 0.3 V (min -0.3 V)
- Input current on SDA, SCL, GND: -280 mA to 100 mA
- Short term storage temperature: -40 to 70 °C
- ESD: HBM 2 kV, CDM 500 V
Key Specs:
- CO2 accuracy (SCD40, 400–2,000 ppm): ±(50 ppm + 5% of reading); output range 0–40,000 ppm
- CO2 repeatability: ±10 ppm typ.; response time τ63% 60 s typ.
- Humidity accuracy: ±6 %RH typ. (15–35 °C, 20–65 %RH); ±9 %RH typ. (-10 to 60 °C)
- Temperature accuracy: ±0.8 °C typ. (15–35 °C); ±1.5 °C typ. (-10 to 60 °C)
- Peak supply current: 175 mA typ., 205 mA max (VDD = 3.3 V); 115 mA typ., 137 mA max (5 V)
- Average supply current, periodic measurement (1 per 5 s): 15 mA typ., 18 mA max (3.3 V); 11 mA typ., 13 mA max (5 V)
- Average supply current, low power periodic mode (1 per 30 s): 3.2 mA typ., 3.5 mA max (3.3 V)
- Power-up time: 30 ms max; supply ripple: 30 mV pk-pk max
- Additional CO2 drift after five years with ASC: ±(5 ppm + 0.5% of reading) typ.
Features:
- Photoacoustic NDIR sensor technology PASens®
- Smallest form factor: 10.1 x 10.1 x 6.5 mm³
- Reflow solderable
- Digital I²C interface (address 0x62)
- Integrated SHT4x temperature and humidity sensor for on-chip compensation
- Automatic self-calibration (ASC) and forced recalibration
- Sensor lifetime >10 years; REACH and RoHS compliant
Applications:
- Indoor air quality monitors
- Smart ventilation systems
- Connected devices for CO2 monitoring
Package:
- LGA, 10.1 x 10.1 x 6.5 mm, MSL 3
- Tape & reel
SCD40-D-R2 Features
- Photoacoustic NDIR sensor technology PASens®
- Smallest form factor: 10.1 x 10.1 x 6.5 mm 3
- Reflow solderable for cost-effective assembly
- Digital I 2 C interface
- Integrated temperature and humidity sensor
SCD40-D-R2 Electrical Characteristics
| Parameter | Symbol | Conditions | Min. | Typical | Max. | Units |
|---|---|---|---|---|---|---|
| Supply voltage DC 6 | V DD | 2.4 | 3.3 or 5.0 | 5.5 | V | |
| Unloaded supply voltage ripple peak to peak 7 | V RPP | 30 | mV | |||
| Peak supply current 8 | I peak | V DD = 3.3 V | 175 | 205 | mA | |
| Peak supply current 8 | I peak | V DD = 5 V | 115 | 137 | mA | |
| Average supply current for periodic measurement mode, 1 measurement every 5 seconds | I DD | V DD = 3.3 V | 15 | 18 | mA | |
| Average supply current for periodic measurement mode, 1 measurement every 5 seconds | I DD | V DD = 5 V | 11 | 13 | mA | |
| Average supply current for low power periodic measurement mode, 1 measurement every 30 seconds | I DD | V DD = 3.3 V | 3.2 | 3.5 | mA | |
| Average supply current for low power periodic measurement mode, 1 measurement every 30 seconds | I DD | V DD = 5 V | 2.8 | 3 | mA | |
| Average supply current for single shot mode, 1 measurement every 5 minutes (SCD41 only) 9 | I DD | V DD = 3.3 V | 0.45 | 0.5 | mA | |
| Average supply current for single shot mode, 1 measurement every 5 minutes (SCD41 only) 9 | I DD | V DD = 5 V | 0.36 | 0.4 | mA | |
| Input high level voltage | V IH | 0.65 x V DD | 1 x V DD | - | ||
| Input low level voltage | V IL | 0.3 x V DD | - | |||
| Output low level voltage | V OL | 3 mA sink current | 0.66 | V |
Table 4 : SCD4x electrical specifications
SCD40-D-R2 Absolute Maximum Ratings
Stress levels beyond those listed in Table 5 may cause permanent damage to the device. Exposure to minimum/maximum rating conditions for extended periods may affect sensor performance and device reliability.
Table 5 : SCD4x operation conditions, lifetime and maximum ratings
| Parameter | Conditions | Value |
|---|---|---|
| Temperature operating conditions | -10 - 60 °C | |
| Humidity operating conditions 10 | Non-condensing | 0 - 95 %RH |
| MSL Level | 3 | |
| DC supply voltage | -0.3 V - 6.0 V | |
| Max voltage on pins SDA, SCL, GND | -0.3 V - V DD + 0.3 V | |
| Input current on pins SDA, SCL, GND | -280 mA - 100 mA | |
| Short term storage temperature 11 | -40 °C - 70 °C | |
| Recommended storage temperature | 10 °C - 50 °C | |
| ESD HBM (pads and metal cap) | 2 kV | |
| ESD CDM | 500 V | |
| Maintenance Interval | Maintenance free when the ASC algorithm 12 is used. | None |
| Sensor lifetime 13 | Typical operating conditions | >10 years |
6 Supply voltage must be kept constant for stable sensor operation.
7 Valid only for the supply voltage without the load of the sensor.
8 Refers to sustained current.
9 On-demand measurement with freely adjustable interval. See Section 3.10.
10 Accuracy can be reduced at relative humidity levels lower than 10%.
11 Short term storage refers to temporary conditions during e.g., transport.
12 For proper function of the ASC field-calibration algorithm, the SCD4x must be exposed to air with CO2 concentrations of 400 ppm on a weekly basis.
13 Sensor tested over simulated lifetime of >10 years for indoor environment mission profile.
SCD40-D-R2 Package Information
Figure 3 schematically displays the package outline, as well as key nominal dimensions and their tolerances in millimeters. The notched corner of the protection membrane serves as a polarity mark to indicate the location of pin 1. Note that the white protection membrane on top of the sensor must not be removed or tampered with to ensure proper sensor operation. The weight of the sensor is approx. 0.6 g.
Figure 3 : Packaging outline drawing of the SCD4x: (left) top view and (right) side view. Dimensions are given in millimeters.
Figure 3 schematically displays the package outline, as well as key nominal dimensions and their tolerances in millimeters. The notched corner of the protection membrane serves as a polarity mark to indicate the location of pin 1. Note that the white protection membrane on top of the sensor must not be removed or tampered with to ensure proper sensor operation. The weight of the sensor is approx. 0.6 g.
Variants on the same datasheet
These parts have exact links to the same datasheet. They are candidates to compare, not verified drop-in replacements; check package, pinout and electrical limits.
| Part Number | Manufacturer | Package |
|---|---|---|
| SCD40 | Sensirion | — |
| SCD40-D-R1 | Sensirion | SMD |
| SCD41 | ABB Electrification (Thomas and Betts) |
Other Temperature Sensors
- BME280 – Bosch Sensortec, Digital Humidity, Pressure, and Temperature Sensor
- SHT30 – Sensirion, Humidity and Temperature Sensor
- Si7021 – Silicon Labs, I2C Humidity and Temperature Sensor
- SHT31-DIS-B2.5kS – Sensirion, Digital Humidity and Temperature Sensor
- TMP116NAIDRVR – Texas Instruments, Digital Temperature Sensor
- BME280.C – Bosch Sensortec, Digital Humidity, Pressure, and Temperature Sensor
- BME280.H – Bosch Sensortec, Digital Humidity, Pressure, and Temperature Sensor
- DS18B20 – Analog Devices, Digital Thermometer
All Temperature Sensors datasheetsAll Sensirion datasheets (20)
Ask your AI agent about the SCD40-D-R2
Connect SheetsData to Claude, Cursor, Codex or any MCP client and your agent reads this datasheet for you: pinout, limits, register maps and design checks, with the numbers taken from the PDF.
claude mcp add --transport http sheetsdata https://mcp.sheetsdata.com/mcp
Then ask: "Can the SCD40-D-R2 run from my 12 V rail? Check it against the datasheet limits."
Create a free account $2 of usage every month, no card needed.