Skip to main content

We use cookies to understand how you use our site and improve your experience. See our Privacy Policy.

HRB1-S-DC5V

Relay

The HRB1-S-DC5V is a relay from Xiamen Hongfa. View the full HRB1-S-DC5V datasheet below including key specifications.

Official HRB1-S-DC5V datasheet (PDF) — the source this page was extracted from.

Manufacturer

Xiamen Hongfa

Category

Relays

Package

DIP,12.3x7.3mm

HRB1-S-DC5V Key Specifications

ParameterValue
WeightApproximately 2.2g
Coil Power150mW
Contact Form1 Form C (SPDT)
Operate TimeMax 5ms
Release TimeMax 5ms
Coil Resistance167 ohm ±10%
Electrical Life100,000 operations
Mechanical Life5,000,000 operations
Operate Voltage3.5VDC
Release Voltage0.5VDC
Contact MaterialAuAg
Safety ApprovalsUL/cUL E164730, CSA 1369391
Min Switching Load5VDC, 10mA
Max Switching Power125VA, 30W
Coil Nominal Voltage5VDC
Insulation ResistanceMin 1,000 MOhm at 500VDC
Max Switching Current1A
Max Switching Voltage125VAC / 30VDC
Operating Temperature-40°C to +70°C
Contact Rating (Resistive)1A 120VAC / 30VDC
Contact Resistance (Initial)Max 50 mOhm (6VDC 1A)
Dielectric Strength (Open Contacts)500VAC, 1min
Dielectric Strength (Coil To Contacts)1,000VAC, 1min

HRB1-S-DC5V Overview

Part: HRB1 Relay

Type: Relay

Description: Miniature relay with 1 Form C contact, 1A switching current, and coil voltage options from 3VDC to 24VDC.

Operating Conditions:

  • Supply voltage: 3–24 VDC
  • Operating temperature: -40 to +70 °C
  • Humidity: 35%–95% RH at +40°C (no frost)

Absolute Maximum Ratings:

  • Max switching voltage: 125 VAC / 30 VDC
  • Max continuous current: 1 A
  • Max switching power: 125 VA, 30 W

Key Specs:

  • Contact Form: 1 Form C
  • Contact Material: AuAg
  • Contact Rating (Resistive): 1 A 120 VAC / 30 VDC
  • Contact Resistance (Initial): Max. 50 mΩ (6 VDC 1 A)
  • Electrical Life: 100,000 operations
  • Mechanical Life: 5,000,000 operations
  • Operate Time: Max. 5 ms
  • Release Time: Max. 5 ms
  • Insulation Resistance: Min. 1,000 MΩ (500 VDC)
  • Dielectric Strength (Coil to Contacts): 1,000 VAC, 1 min

Features:

  • UL/cUL safety approval (NO.E164730)
  • CSA safety approval (NO.1369391)

Package:

  • Approximately 2.2g weight

More part numbers on this datasheet

Their pages show this same datasheet. Some are linked through their part family rather than checked part by part, so confirm the exact part in the ordering information.

Other Relays

  • TX2-4.5V – Panasonic, Signal Relay
  • TX2-5V – Panasonic
  • G6K-2F – Omron Electronics Inc-EMC Div, Surface Mounting Relay
  • G6K-2F-DC5 – Omron, DPDT Low Signal Relay
  • G6K-2F-TR – Omron Electronics Inc-EMC Div, Surface Mounting Relay
  • G6K-2F-Y – Omron Electronics Inc-EMC Div, Surface Mounting Relay
  • G6K-2F-Y-DC5 – Omron, Low Signal Relay
  • G6K-2F-Y-TR – Omron, Surface Mounting Relay

All Relays datasheetsAll Xiamen Hongfa datasheets (8)

Data on this page is extracted from publicly available manufacturer datasheets using automated tools including AI. It may contain errors or omissions. Always verify specifications against the official manufacturer datasheet before making design or purchasing decisions. See our Terms of Service. Rights holders can submit a takedown request.

Ask your AI agent about the HRB1-S-DC5V

Connect SheetsData to Claude, Cursor, Codex or any MCP client and your agent reads this datasheet for you: pinout, limits, register maps and design checks, with the numbers taken from the PDF.

claude mcp add --transport http sheetsdata https://mcp.sheetsdata.com/mcp

Then ask: "Can the HRB1-S-DC5V run from my 12 V rail? Check it against the datasheet limits."

Create a free account $2 of usage every month, no card needed.