G6K-2F-DC5
DPDT Low Signal RelayThe G6K-2F-DC5 is a dpdt low signal relay from Omron. View the full G6K-2F-DC5 datasheet below including key specifications.
G6K-2F-DC5 shares its datasheet with G6K-2F-Y-DC5, whose page lists every part number it covers.
Official G6K-2F-DC5 datasheet (PDF) — the source this page was extracted from.
G6K-2F-DC5 Key Specifications
| Parameter | Value |
|---|---|
| Weight | Approx. 0.7 g |
| Rated Load | 0.3 A at 125 VAC; 1 A at 30 VDC |
| Contact Form | DPDT |
| Operate Time | 3 ms max. |
| Release Time | 3 ms max. |
| Coil Resistance | 237 Ω |
| Dropout Voltage | 10% of rated voltage min. |
| Pick-Up Voltage | 80% of rated voltage max. |
| Contact Material | Ag (Au clad) |
| Contact Resistance | 100 mΩ max. |
| Max. Carry Current | 1 A |
| Rated Coil Current | 21.1 mA |
| Rated Coil Voltage | 5 VDC |
| Maximum Coil Voltage | 150% of rated voltage max. |
| Insulation Resistance | 1,000 MΩ min. (at 500 VDC) |
| Min. Permissible Load | 10 μA at 10 mVDC |
| Operating Temperature | -40°C to 70°C |
| Coil Power Consumption | Approx. 100 mW |
| Max. Operating Voltage | 125 VAC, 60 VDC |
| Electrical Service Life | 100,000 operations min. |
| Max. Switching Capacity | 37.5 VA, 30 W |
| Mechanical Service Life | 50,000,000 operations min. |
G6K-2F-DC5 Overview
Part: G6K — Omron
Type: Low Signal Relay
Description: Compact DPDT low signal relay available in non-latching and single coil latching versions, with 2.54 mm or 3.2 mm coil-contact terminal spacing, capable of switching 1 A at 30 VDC or 0.3 A at 125 VAC, and featuring a coil power consumption of approximately 100 mW.
Operating Conditions:
- Supply voltage: 3–24 VDC (coil rated voltage)
- Operating temperature: -40 °C to 70 °C
- Humidity: 5 to 85% RH
Absolute Maximum Ratings:
- Max operating voltage (contacts): 125 VAC, 60 VDC
- Max continuous current (contacts): 1 A
- Max coil voltage: 150% of rated value @23 °C to 70 °C
Key Specs:
- Rated load: 0.3 A at 125 VAC, 1 A at 30 VDC
- Contact material: Ag (Au clad)
- Max. switching capacity: 37.5 VA, 30W
- Min. permissible load: 10 μA at 10 mVDC
- Coil power consumption: Approx. 100 mW
- Contact resistance: 100 mΩ max. (at 10 mA, 1 VDC)
- Operate (set) time: 3 ms max.
- Dielectric strength (coil-contacts): 1,500 VAC for 1 minute
Features:
- Compact fourth generation design
- Available in 2.54 and 3.2 mm coil-contact terminal spacing
- '-Y' models meet 2.5 kV Bellcore surge requirements
- Conforms to FCC Part 68
- Available in PCB through-hole, SMT gullwing and SMT 'inside-L' terminals
- UL recognized / CSA certified
- Available in single coil latching
- RoHS Compliant
Package:
- Gullwing
- Inside 'L'
- PCB through-hole
Variants on the same datasheet
These parts have exact links to the same datasheet. They are candidates to compare, not verified drop-in replacements; check package, pinout and electrical limits.
| Part Number | Manufacturer | Package |
|---|---|---|
| G6K-2F | Omron Electronics Inc-EMC Div | Gullwing |
| G6K-2F-Y | Omron Electronics Inc-EMC Div | Outside-L surface mounting terminals |
| G6K-2F-Y-DC5 | Omron | SMT gullwing |
| G6K-2G | Omron Electronics Inc-EMC Div | — |
| G6K-2G-TR-DC5 | Omron | Inside "L" |
| G6K-2G-Y | Omron Electronics Inc-EMC Div | — |
| G6K-2P | Omron Electronics Inc-EMC Div | — |
| G6K-2P-Y | Omron Electronics Inc-EMC Div | — |
| G6KU-2F-Y | Omron Electronics Inc-EMC Div | — |
| G6KU-2G-Y | Omron Electronics Inc-EMC Div | — |
| G6KU-2P-Y | Omron Electronics Inc-EMC Div | — |
Other Relays
- TX2-4.5V – Panasonic, Signal Relay
- TX2-5V – Panasonic
- G6K-2F – Omron Electronics Inc-EMC Div, Surface Mounting Relay
- G6K-2F-TR – Omron Electronics Inc-EMC Div, Surface Mounting Relay
- G6K-2F-Y – Omron Electronics Inc-EMC Div, Surface Mounting Relay
- G6K-2F-Y-DC5 – Omron, Low Signal Relay
- G6K-2F-Y-TR – Omron, Surface Mounting Relay
- G6K-2G – Omron Electronics Inc-EMC Div, Surface Mounting Relay
Ask your AI agent about the G6K-2F-DC5
Connect SheetsData to Claude, Cursor, Codex or any MCP client and your agent reads this datasheet for you: pinout, limits, register maps and design checks, with the numbers taken from the PDF.
claude mcp add --transport http sheetsdata https://mcp.sheetsdata.com/mcp
Then ask: "Can the G6K-2F-DC5 run from my 12 V rail? Check it against the datasheet limits."
Create a free account $2 of usage every month, no card needed.