SN54HC125FK Key Specifications
| Parameter | Value |
|---|---|
| VOH (74, 25 °C) | min 4.4 V at VCC = 4.5 V, IOH = -20 μA; min 3.98 V at IOH = -6 mA |
| VOL (74, 25 °C) | max 0.1 V at IOL = 20 μA; max 0.26 V at VCC = 4.5 V, IOL = 6 mA |
| Input leakage current (74) | ±0.1 μA at 25 °C, ±1 μA over -40 to 85 °C (VCC = 6 V) |
| Three-state leakage current (74) | ±0.5 μA max at 25 °C, ±5 μA max over -40 to 85 °C (VCC = 6 V) |
| Supply current ICC (74) | 8 μA max at 25 °C, 80 μA max over -40 to 85 °C (VCC = 6 V) |
| Propagation delay A to Y (74, CL = 50 pF) | 14 ns typ and 24 ns max at 4.5 V, 25 °C; 36 ns max over -40 to 85 °C |
| Transition time (74, CL = 50 pF) | 8 ns typ and 12 ns max at 4.5 V, 25 °C |
| Input capacitance | 3 pF typ, 10 pF max |
| ESD | HBM ±2000 V, CDM ±500 V |
| Thermal resistance RθJA | 63.0 °C/W (PDIP) to 151.7 °C/W (TSSOP) |
SN54HC125FK Overview
Part: SN74HC125 / SN54HC125 (SNx4HC125) — Texas Instruments
Type: Quadruple Buffer with 3-State Outputs
Description: Quad independent non-inverting buffers with active-low output enables (Y = A), operating from 2–6 V, with ±35 mA continuous output current rating and 14 ns typical propagation delay at 4.5 V, 50 pF.
Operating Conditions:
- Supply voltage: 2–6 V
- Operating temperature: -40 to 85 °C for SN74HC125 (SN54HC125 is rated -55 to 125 °C)
- Input transition time: max 1000 ns at 2 V, 500 ns at 4.5 V, 400 ns at 6 V
- High-level input voltage (min): 1.5 V at 2 V, 3.15 V at 4.5 V, 4.2 V at 6 V
Absolute Maximum Ratings:
- Max supply voltage: 7 V (min -0.5 V)
- Max continuous output current: ±35 mA
- Max continuous current through VCC or GND: ±70 mA
- Input/output clamp current: ±20 mA
- Max junction temperature: 150 °C
- Storage temperature: -65 to 150 °C
Key Specs:
- VOH (74, 25 °C): min 4.4 V at VCC = 4.5 V, IOH = -20 μA; min 3.98 V at IOH = -6 mA
- VOL (74, 25 °C): max 0.1 V at IOL = 20 μA; max 0.26 V at VCC = 4.5 V, IOL = 6 mA
- Input leakage current (74): ±0.1 μA at 25 °C, ±1 μA over -40 to 85 °C (VCC = 6 V)
- Three-state leakage current (74): ±0.5 μA max at 25 °C, ±5 μA max over -40 to 85 °C (VCC = 6 V)
- Supply current ICC (74): 8 μA max at 25 °C, 80 μA max over -40 to 85 °C (VCC = 6 V)
- Propagation delay A to Y (74, CL = 50 pF): 14 ns typ and 24 ns max at 4.5 V, 25 °C; 36 ns max over -40 to 85 °C
- Transition time (74, CL = 50 pF): 8 ns typ and 12 ns max at 4.5 V, 25 °C
- Input capacitance: 3 pF typ, 10 pF max
- ESD: HBM ±2000 V, CDM ±500 V
- Thermal resistance RθJA: 63.0 °C/W (PDIP) to 151.7 °C/W (TSSOP)
Features:
- Buffered inputs
- Wide operating voltage range: 2 V to 6 V
- Supports fanout up to 10 LSTTL loads
- Significant power reduction compared to LSTTL logic ICs
- Four independent buffers with 3-state outputs
Applications:
- Enable digital signals
Package:
- SOIC (14), 8.70 mm × 3.90 mm (SN74HC125D)
- SSOP (14), 6.50 mm × 5.30 mm (SN74HC125DB)
- PDIP (14), 19.30 mm × 6.40 mm (SN74HC125N)
- SO (14), 10.20 mm × 5.30 mm (SN74HC125NS)
- TSSOP (14), 5.00 mm × 4.40 mm (SN74HC125PW)
- CDIP (14), 21.30 mm × 7.60 mm (SN54HC125J)
- LCCC (20), 8.90 mm × 8.90 mm (SN54HC125FK)
SN54HC125FK Features
- Buffered inputs
- Wide operating voltage range: 2 V to 6 V
- Wide operating temperature range: -40°C to +85°C
- Supports fanout up to 10 LSTTL loads
- Significant power reduction compared to LSTTL logic ICs
SN54HC125FK Applications
SN74HC125, SN54HC125 SCLS104F - AUGUST 1984 - REVISED APRIL 2021 SN74HC125, SN54HC125
SN54HC125FK Pin Configuration
Figure 5-1. D, DB, N, NS, PW, or J Package 14-Pin SOIC, SSOP, PDIP, SO, TSSOP, or CDIP Top View
SN54HC125FK Electrical Characteristics
over operating free-air temperature range; typical values measured at T A = 25°C (unless otherwise noted).
| PARAMETER | PARAMETER | TEST CONDITIONS | TEST CONDITIONS | V CC | Operating free-air temperature (T A ) - 25°C - MIN | Operating free-air temperature (T A ) - 25°C - TYP | Operating free-air temperature (T A ) - 25°C - MAX | Operating free-air temperature (T A ) - -40°C to 85°C - MIN | Operating free-air temperature (T A ) - -40°C to 85°C - TYP | Operating free-air temperature (T A ) - -40°C to 85°C - MAX | UNIT |
|---|---|---|---|---|---|---|---|---|---|---|---|
| V OH | High-level output voltage | V I = V IH or V IL | I OH = -20 μA | 2 V | 1.9 | 1.998 | 1.9 | V | |||
| V OH | High-level output voltage | V I = V IH or V IL | I OH = -20 μA | 4.5 V | 4.4 | 4.499 | 4.4 | V | |||
| V OH | High-level output voltage | V I = V IH or V IL | I OH = -20 μA | 6 V | 5.9 | 5.999 | 5.9 | V | |||
| V OH | High-level output voltage | V I = V IH or V IL | I OH = -6 mA | 4.5 V | 3.98 | 4.3 | 3.84 | V | |||
| V OH | High-level output voltage | V I = V IH or V IL | I OH = -7.8 mA | 6 V | 5.48 | 5.8 | 5.34 | V | |||
| V OL | Low-level output voltage | V I = V IH or V IL | I OL = 20 μA | 2 V | 0.002 | 0.1 | 0.1 | V | |||
| V OL | Low-level output voltage | V I = V IH or V IL | I OL = 20 μA | 4.5 V | 0.001 | 0.1 | 0.1 | V | |||
| V OL | Low-level output voltage | V I = V IH or V IL | I OL = 20 μA | 6 V | 0.001 | 0.1 | 0.1 | V | |||
| V OL | Low-level output voltage | V I = V IH or V IL | I OL = 6 mA | 4.5 V | 0.17 | 0.26 | 0.33 | V | |||
| V OL | Low-level output voltage | V I = V IH or V IL | I OL = 7.8 mA | 6 V | 0.15 | 0.26 | 0.33 | V | |||
| I I | Input leakage current | V I = V CC or 0 | V I = V CC or 0 | 6 V | ±0.1 | ±0.1 | ±0.1 | ±1 | μA | ||
| I OZ | Three-state leakage current | V O = V CC or 0 | 6 V | ±0.01 | ±0.5 | ±5 | μA | ||||
| I CC | Supply current | V I = V CC or 0 | I O = 0 | 6 V | 8 | 8 | 8 | 80 | μA | ||
| C i | Input capacitance | 2 V to 6 V | 3 10 | 3 10 | 3 10 | 10 | pF |
SN54HC125FK Absolute Maximum Ratings
over operating free-air temperature range (unless otherwise noted) (1)
| MIN | MAX | UNIT | |||
|---|---|---|---|---|---|
| V CC | Supply voltage | Supply voltage | -0.5 | 7 | V |
| I IK | Input clamp current (2) | V I < 0 or V I > V CC | ±20 | mA | |
| I OK | Output clamp current (2) | V O < 0 or V O > V CC | ±20 | mA | |
| I O | Continuous output current | V O = 0 to V CC | ±35 | mA | |
| Continuous current through V CC or GND | Continuous current through V CC or GND | ±70 | mA | ||
| T J | Junction temperature (3) | Junction temperature (3) | 150 | °C | |
| T stg | Storage temperature | Storage temperature | -65 | 150 | °C |
- (2) The input and output voltage ratings may be exceeded if the input and output current ratings are observed.
- (3) Guaranteed by design.
SN54HC125FK Recommended Operating Conditions
over operating free-air temperature range (unless otherwise noted)
| V CC | Supply voltage | MIN - 2 | NOM - 5 | MAX - 6 | UNIT - V | |
|---|---|---|---|---|---|---|
| V IH | High-level input voltage | V CC = 2 V | 1.5 | V | ||
| V IH | High-level input voltage | V CC = 4.5 V | 3.15 | V | ||
| V IH | High-level input voltage | V CC = 6 V | 4.2 | V | ||
| V IL | Low-level input voltage | V CC = 2 V | 0.5 | V | ||
| V IL | Low-level input voltage | V CC = 4.5 V | 1.35 | V | ||
| V IL | Low-level input voltage | V CC = 6 V | 1.8 | V | ||
| V I | Input voltage | 0 | V CC | V | ||
| V O | Output voltage | 0 | V CC | V | ||
| t t | Input transition time | V CC = 2 V | 1000 | ns | ||
| t t | Input transition time | V CC = 4.5 V | 500 | ns | ||
| t t | Input transition time | V CC = 6 V | 400 | ns | ||
| T A | Operating free-air temperature | -55 | 125 | °C |
SN54HC125FK Thermal Information
| THERMAL METRIC (1) | THERMAL METRIC (1) | SN74HC125 - D (SOIC) - 14 PINS | SN74HC125 - DB (SSOP) - 14 PINS | SN74HC125 - N (PDIP) - 14 PINS | SN74HC125 - NS (SO) - 14 PINS | SN74HC125 - PW (TSSOP) - 14 PINS | UNIT |
|---|---|---|---|---|---|---|---|
| R θJA | Junction-to-ambient thermal resistance | 133.6 | 108.0 | 63.0 | 122.6 | 151.7 | °C/W |
| R θJC(top) | Junction-to-case (top) thermal resistance | 89 | 57.8 | 50.7 | 81.8 | 79.4 | °C/W |
| R θJB | Junction-to-board thermal resistance | 89.5 | 58.3 | 42.7 | 83.8 | 94.7 | °C/W |
| Ψ JT | Junction-to-top characterization parameter | 45.5 | 18.0 | 30.3 | 45.4 | 25.2 | °C/W |
| Ψ JB | Junction-to-board characterization parameter | 89.1 | 57.6 | 42.5 | 83.4 | 94.1 | °C/W |
| R θJC(bot) | Junction-to-case (bottom) thermal resistance | N/A | N/A | N/A | N/A | N/A | °C/W |
SN54HC125FK Typical Application
In this application, a 3-state buffer is used to enable or disable a data connection as shown in Figure 9-1 . It is common to see all four channels of a device used together for controlling a 4-bit data bus, however each channel of the device can be used independently. Unused channels should have the inputs terminated at ground or VCC and the output left unconnected.
When the output of the device is active, the data signal will be replicated at the output. When the output of the device is disabled, the output will be in a high-impedance state, and the output voltage will be determined by the circuit connected to the output pin. This circuit is most commonly used when a bus must be completely disabled. One example of this situation is when the circuitry connected to the output is to be powered off for an extended period of time to save system power, and the inputs to that circuitry cannot have a voltage present due to protective clamp diodes.
Variants on the same datasheet
These parts have exact links to the same datasheet. They are candidates to compare, not verified drop-in replacements; check package, pinout and electrical limits.
| Part Number | Manufacturer | Package |
|---|---|---|
| SN54HC125J | Texas Instruments | CDIP (14) |
| SN74HC125 | Texas Instruments | SOIC (14) |
| SN74HC125D | Texas Instruments | SOIC (14) |
| SN74HC125DB | Texas Instruments | SSOP (14) |
| SN74HC125N | Texas Instruments | PDIP (14) |
| SN74HC125NS | Texas Instruments | SO (14) |
| SN74HC125PW | Texas Instruments | TSSOP (14) |
More datasheets
Ask your AI agent about the SN54HC125FK
Connect SheetsData to Claude, Cursor, Codex or any MCP client and your agent reads this datasheet for you: pinout, limits, register maps and design checks, with the numbers taken from the PDF.
claude mcp add --transport http sheetsdata https://mcp.sheetsdata.com/mcp
Then ask: "Can the SN54HC125FK run from my 12 V rail? Check it against the datasheet limits."
Create a free account $2 of usage every month, no card needed.