SHT3X-DIS
Humidity and Temperature SensorThe SHT3X-DIS is a humidity and temperature sensor from Sensirion. View the full SHT3X-DIS datasheet below including key specifications, electrical characteristics, absolute maximum ratings.
SHT3X-DIS shares its datasheet with SHT31, whose page lists every part number it covers.
Official SHT3X-DIS datasheet (PDF) — the source this page was extracted from.
SHT3X-DIS Key Specifications
| Parameter | Value |
|---|---|
| Heater Power | 3.6 mW to 33 mW |
| Power-Up Time | 0.5 ms typ., 1 ms max |
| Supply Voltage | 2.15V to 5.5V |
| Package Dimensions | 2.5 x 2.5 mm, 0.9 mm height |
| Humidity Resolution | 0.01 %RH |
| Average Supply Current | 1.7 µA (1 measurement/s, lowest repeatability) |
| Temperature Resolution | 0.01 °C |
| Communication Interface | I2C up to 1 MHz, two selectable addresses |
| Humidity Specified Range | 0 to 100 %RH |
| Supply Current (Measuring) | 600 µA typ., 1500 µA max |
| Temperature Specified Range | -40°C to 125°C |
| Humidity Response Time (63%) | 8 s |
| Humidity Repeatability (High) | 0.08 %RH |
| Humidity Accuracy (SHT35 Typ.) | ±1.5 %RH |
| Temperature Repeatability (High) | 0.04 °C |
| Temperature Accuracy (SHT35 Typ.) | ±0.1 °C |
| Humidity Accuracy (SHT30/SHT31 Typ.) | ±2 %RH |
| Temperature Accuracy (SHT30/SHT31 Typ.) | ±0.2 °C |
| Supply Current (Idle, Single Shot, 25°C) | 0.2 µA typ., 2.0 µA max |
SHT3X-DIS Overview
Part: SHT31 — Sensirion
Type: Humidity and Temperature Sensor
Description: Fully calibrated digital humidity and temperature sensor with I2C interface, operating from 2.15 V to 5.5 V with typical accuracy of ±2 %RH and 0.2 °C in a compact 8-pin DFN package.
Operating Conditions:
- Supply voltage: 2.15 to 5.5 V
- Operating temperature: -40 to 125 °C
- Recommended temperature range: 5 to 60 °C
- Recommended humidity range: 20 to 80 %RH
Absolute Maximum Ratings:
- Max supply voltage: 6 V
- Max junction/storage temperature: 150 °C
Key Specs:
- Relative humidity accuracy tolerance (SHT31): ±2 %RH (typ. at 25 °C)
- Temperature accuracy tolerance (SHT31): 0.2 °C (typ., 0 °C to 90 °C)
- Relative humidity range: 0 to 100 %RH
- Temperature range: -40 to 125 °C
- Relative humidity resolution: 0.01 %RH
- Temperature resolution: 0.01 °C
- Relative humidity response time (τ63%): 8 s (at 25 °C, 1 m/s airflow)
- Temperature response time (τ63%): >2 s
- Supply current (measuring): 600 μA typ., 1500 μA max
- Supply current (idle, single shot mode, 25 °C): 0.2 μA typ., 2.0 μA max
- Power-up time: 0.5 ms typ., 1 ms max (hard reset, VDD ≥ 2.4 V)
Features:
- Fully calibrated, linearized, and temperature-compensated digital output
- I2C interface supporting speeds up to 1 MHz with clock stretching support
- Two user-selectable I2C addresses via ADDR pin
- Programmable alert output pin for threshold monitoring
- Integrated heater with selectable 3.6 to 33 mW power
- Fast measurement and start-up times with selectable repeatability modes
Applications:
- Humidity and temperature monitoring in mass production systems
- Diverse embedded sensor assemblies requiring broad supply voltage compatibility
Package:
- 8-Pin DFN (2.5 × 2.5 × 0.9 mm)
SHT3X-DIS Pin Configuration
The SHT3x-DIS comes in a 8-pin DFN package - see Table 7.
Table 7 SHT3x-DIS pin assignment (transparent top view). Dashed lines are only visible if viewed from below. The die pad is internally connected to VSS.
| Pin | Name | Comments |
|---|---|---|
| 1 | SDA | Serial data; input / output |
| 2 | ADDR | Address pin; input; connect to either logic high or low, do not leave floating |
| 3 | ALERT | Indicates alarm condition; output; must be left floating if unused |
| 4 | SCL | Serial clock; input / output |
| 5 | VDD | Supply voltage; input |
| 6 | nRESET | Reset pin active low; input; if not used it is recommended to be left floating; can be connected to VDD with a series resistor of R ≥2 kΩ |
| 7 | R | No electrical function; to be connected to VSS |
| 8 | VSS | Ground |
| 1 2 3 4 | 1 2 3 4 | 1 2 3 4 |
SHT3X-DIS Electrical Characteristics
| Parameter | Symbol | Condition | Min. | Typ. | Max. | Units | Comments |
|---|---|---|---|---|---|---|---|
| Supply voltage | V DD | 2.15 | 3.3 | 5.5 | V | ||
| Power-up/down level | V POR | 1.8 | 2.10 | 2.15 | V | ||
| Slew rate change of the supply voltage | V DD,slew | - | - | 20 | V/ms | Voltage changes on the VDD line between V DD,min and V DD , max should be slower than the maximum slew rate; faster slew rates may lead to reset; | |
| Supply current | I DD | idle state (single shot mode) T=25°C | - | 0.2 | 2.0 | A | Current when sensor is not performing a measurement during single shot mode |
| Supply current | I DD | idle state (single shot mode) T=125°C | - | - | 6.0 | A | Current when sensor is not performing a measurement during single shot mode |
| Supply current | I DD | idle state (periodic data acquisition mode) | - | 45 | - | A | Current when sensor is not performing a measurement during periodic data acquisition mode |
| Supply current | I DD | Measuring | - | 600 | 1500 | A | Current consumption while sensor is measuring |
| Supply current | I DD | Average | - | 1.7 | - | A | Current consumption (operation with one measurement per second at lowest repeatability, single shot mode) |
| Alert Output driving strength | IOH | 1.5x V DD | mA | See also section 3.5 | |||
| Heater power | P Heater | Heater running | 3.6 | - | 33 | mW | Depending on the supply voltage |
Table 3 Electrical specifications, typical values are valid for T=25°C, min. & max. values for T=-40°C … 125°C
SHT3X-DIS Absolute Maximum Ratings
Stress levels beyond those listed in Table 6 may cause permanent damage to the device or affect the reliability of the sensor. These are stress ratings only and functional operation of the device at these conditions is not guaranteed. Ratings are only tested each at a time.
| Parameter | Rating | Units |
|---|---|---|
| Supply voltage V DD | -0.3 to 6 | V |
| Max Voltage on pins (pin 1 (SDA); pin 2 (ADDR); pin 3 (ALERT); pin 4 (SCL); pin 6 (nRESET)) | -0.3 to VDD+0.3 | V |
| Input current on any pin | ±100 | mA |
| Operating temperature range | -40 to 125 | °C |
| Storage temperature range | -40 to 150 | °C |
| ESD HBM (human body model) 9 | 4 | kV |
| ESD CDM (charge device model) 10 | 750 | V |
Table 6 Minimum and maximum ratings; voltages may only be applied for short time periods.
9 According to ANSI/ESDA/JEDEC JS-001-2014; AEC-Q100-002.
10 According to ANSI/ESD S5.3.1-2009; AEC-Q100-011.
SHT3X-DIS Recommended Operating Conditions
The sensor shows best performance when operated within recommended normal temperature and humidity range of 5 °C - 60 °C and 20 %RH - 80 %RH, respectively. Long-term exposure to conditions outside normal range, especially at high humidity, may temporarily offset the RH signal (e.g. +3%RH after 60h kept at >80%RH). After returning into the normal temperature and humidity range the sensor will slowly come back to calibration state by itself. Prolonged exposure to extreme conditions may accelerate ageing. To ensure stable operation of the humidity sensor, the conditions described in the document 'SHTxx Assembly of SMD Packages', section 'Storage and Handling Instructions' regarding exposure to volatile organic compounds have to be met. Please note as well that this does apply not only to transportation and manufacturing, but also to operation of the SHT3x-DIS.
SHT3X-DIS Package Information
Figure 15 shows the land pattern. The land pattern is understood to be the open metal areas on the PCB, onto which the DFN pads are soldered.
The solder mask is understood to be the insulating layer on top of the PCB covering the copper traces. It is recommended to design the solder pads as a NonSolder Mask Defined (NSMD) type. For NSMD pads, the solder mask opening should provide a 60 μm to 75 μm design clearance between any copper pad and solder mask. As the pad pitch is only 0.5 mm we recommend to have one solder mask opening for all 4 I/O pads on one side.
Figure 15 shows the land pattern. The land pattern is understood to be the open metal areas on the PCB, onto which the DFN pads are soldered.
For solder paste printing it is recommended to use a laser-cut, stainless steel stencil with electro-polished trapezoidal walls and with 0.1 or 0.125 mm stencil thickness. The length of the stencil apertures for the I/O pads should be the same as the PCB pads. However, the position of the stencil apertures should have an offset of 0.1 mm away from the center of the package. The die pad aperture should cover about 70 - 90 % of the die pad area -thus it should have a size of about 0.9 mm x 1.6 mm.
For information on the soldering process and further recommendation on the assembly process please consult the Application Note HT_AN_SHTxx_Assembly_of_SMD_Packages , which can be found on the Sensirion webpage.
Variants on the same datasheet
These parts have exact links to the same datasheet. They are candidates to compare, not verified drop-in replacements; check package, pinout and electrical limits.
Other Temperature Sensors
- BME280 – Bosch Sensortec, Digital Humidity, Pressure, and Temperature Sensor
- SHT30 – Sensirion, Humidity and Temperature Sensor
- Si7021 – Silicon Labs, I2C Humidity and Temperature Sensor
- SHT31-DIS-B2.5kS – Sensirion, Digital Humidity and Temperature Sensor
- TMP116NAIDRVR – Texas Instruments, Digital Temperature Sensor
- BME280.C – Bosch Sensortec, Digital Humidity, Pressure, and Temperature Sensor
- BME280.H – Bosch Sensortec, Digital Humidity, Pressure, and Temperature Sensor
- DS18B20 – Analog Devices, Digital Thermometer
All Temperature Sensors datasheetsAll Sensirion datasheets (20)
Ask your AI agent about the SHT3X-DIS
Connect SheetsData to Claude, Cursor, Codex or any MCP client and your agent reads this datasheet for you: pinout, limits, register maps and design checks, with the numbers taken from the PDF.
claude mcp add --transport http sheetsdata https://mcp.sheetsdata.com/mcp
Then ask: "Can the SHT3X-DIS run from my 12 V rail? Check it against the datasheet limits."
Create a free account $2 of usage every month, no card needed.