SHT35
Humidity and Temperature SensorThe SHT35 is a humidity and temperature sensor from Sensirion. View the full SHT35 datasheet below including electrical characteristics, absolute maximum ratings.
Manufacturer
Sensirion
Category
Temperature SensorsOverview
Part: Sensirion SHT3x-DIS
Type: Humidity and Temperature Sensor
Description: Fully calibrated, linearized, and temperature compensated digital humidity and temperature sensor with a wide 2.15–5.5 V supply voltage range, I2C interface up to 1 MHz, and typical accuracy of ±1.5 %RH and ±0.1 °C for the SHT35 variant.
Operating Conditions:
- Supply voltage: 2.15–5.5 V
- Operating temperature: -40 to 125 °C
- I2C communication speed: up to 1 MHz
- Humidity specified range: 0 to 100 %RH
- Temperature specified range: -40 to 125 °C
Absolute Maximum Ratings:
- Max supply voltage: 6 V
- Max input current on any pin: ±100 mA
- Max storage temperature: 150 °C
Key Specs:
- SHT35 Humidity accuracy (Typ.): ±1.5 %RH
- SHT35 Temperature accuracy (Typ., 20°C to 60°C): ±0.1 °C
- Humidity resolution (Typ.): 0.01 %RH
- Temperature resolution (Typ.): 0.01 °C
- Supply current (idle state, single shot mode, T=25°C): 0.2 µA (Typ.)
- Supply current (Measuring, Typ.): 600 µA
- Humidity long-term drift (Typ.): <0.25 %RH/yr
- Temperature long-term drift (Max): <0.03 °C/yr
Features:
- Fully calibrated, linearized, and temperature compensated digital output
- I2C Interface with communication speeds up to 1 MHz and two user selectable addresses
- NIST traceability
- Very fast start-up and measurement time
- Enhanced signal processing
- High reliability and long-term stability
Applications:
Package:
- 8-Pin DFN (2.5 x 2.5 mm footprint, 0.9 mm height)
Pin Configuration
The SHT3x-DIS comes in a 8-pin DFN package -see Table 7.
Table 7 SHT3x-DIS pin assignment (transparent top view). Dashed lines are only visible if viewed from below. The die pad is internally connected to VSS.
| Pin | Name | Comments |
|---|---|---|
| 1 | SDA | Serial data; input / output |
| 2 | ADDR | Address pin; input; connect to either logic high or low, do not leave floating |
| 3 | ALERT | Indicates alarm condition; output; must be left floating if unused |
| 4 | SCL | Serial clock; input / output |
| 5 | VDD | Supply voltage; input |
| 6 | nRESET | Reset pin active low; input; if not used it is recommended to be left floating; can be connected to VDD with a series resistor of R ≥2 kΩ |
| 7 | R | No electrical function; to be connected to VSS |
| 8 | VSS | Ground |
Electrical Characteristics
| Parameter | Symbol | Condition | Min. | Typ. | Max. | Units | Comments |
|---|---|---|---|---|---|---|---|
| Supply voltage | V DD | 2.15 | 3.3 | 5.5 | V | ||
| Power-up/down level | V POR | 1.8 | 2.10 | 2.15 | V | ||
| Slew rate change of the supply voltage | V DD,slew | - | - | 20 | V/ms | Voltage changes on the VDD line between V DD,min and V DD , max should be slower than the maximum slew rate; faster slew rates may lead to reset; | |
| Supply current | I DD | idle state (single shot mode) T=25°C | - | 0.2 | 2.0 | A | Current when sensor is not performing a measurement during single shot mode |
| Supply current | I DD | idle state (single shot mode) T=125°C | - | - | 6.0 | A | Current when sensor is not performing a measurement during single shot mode |
| Supply current | I DD | idle state (periodic data acquisition mode) | - | 45 | - | A | Current when sensor is not performing a measurement during periodic data acquisition mode |
| Supply current | I DD | Measuring | - | 600 | 1500 | A | Current consumption while sensor is measuring |
| Supply current | I DD | Average | - | 1.7 | - | A | Current consumption (operation with one measurement per second at lowest repeatability, single shot mode) |
| Alert Output driving strength | IOH | 1.5x V DD | mA | See also section 3.5 | |||
| Heater power | P Heater | Heater running | 3.6 | - | 33 | mW | Depending on the supply voltage |
Table 3 Electrical specifications, typical values are valid for T=25°C, min. & max. values for T=40°C … 125°C
Absolute Maximum Ratings
Stress levels beyond those listed in Table 6 may cause permanent damage to the device or affect the reliability of the sensor. These are stress ratings only and functional operation of the device at these conditions is not guaranteed. Ratings are only tested each at a time.
| Parameter | Rating | Units |
|---|---|---|
| Supply voltage V DD | -0.3 to 6 | V |
| Max Voltage on pins (pin 1 (SDA); pin 2 (ADDR); pin 3 (ALERT); pin 4 (SCL); pin 6 (nRESET)) | -0.3 to VDD+0.3 | V |
| Input current on any pin | ±100 | mA |
| Operating temperature range | -40 to 125 | °C |
| Storage temperature range | -40 to 150 | °C |
| ESD HBM (human body model) 9 | 4 | kV |
| ESD CDM (charge device model) 10 | 750 | V |
Table 6 Minimum and maximum ratings; voltages may only be applied for short time periods.
9 According to ANSI/ESDA/JEDEC JS-001-2014; AEC-Q100-002.
10 According to ANSI/ESD S5.3.1-2009; AEC-Q100-011.
Recommended Operating Conditions
The sensor shows best performance when operated within recommended normal temperature and humidity range of 5 °C -60 °C and 20 %RH -80 %RH, respectively. Long-term exposure to conditions outside normal range, especially at high humidity, may temporarily offset the RH signal (e.g. +3%RH after 60h kept at >80%RH). After returning into the normal temperature and humidity range the sensor will slowly come back to calibration state by itself. Prolonged exposure to extreme conditions may accelerate ageing. To ensure stable operation of the humidity sensor please refer to the document ' Handling instructions SHT ' Please note as well that this does apply not only to transportation and manufacturing, but also to operation of the SHT3x-DIS.
Package Information
Figure 15 shows the land pattern. The land pattern is understood to be the open metal areas on the PCB, onto which the DFN pads are soldered.
The solder mask is understood to be the insulating layer on top of the PCB covering the copper traces. It is recommended to design the solder pads as a NonSolder Mask Defined (NSMD) type. For NSMD pads, the solder mask opening should provide a 60 μm to 75 μm design clearance between any copper pad and solder mask. As the pad pitch is only 0.5 mm we recommend to have one solder mask opening for all 4 I/O pads on one side.
For solder paste printing it is recommended to use a laser-cut, stainless steel stencil with electro-polished trapezoidal walls and with 0.1 or 0.125 mm stencil thickness. The length of the stencil apertures for the I/O pads should be the same as the PCB pads. However, the position of the stencil apertures should have an offset of 0.1 mm away from the center of the package. The die pad aperture should cover about 70 -90 % of the die pad area -thus it should have a size of about 0.9 mm x 1.6 mm.
For information on the soldering process and further recommendation on the assembly process please consult the Handlin Instruction SHT, which can be found on the Sensirion webpage.
Related Variants
The following components are covered by the same datasheet.
Get structured datasheet data via API
Get started free