MS560702BA
Barometric Pressure SensorThe MS560702BA is a barometric pressure sensor from MEAS Switzerland. View the full MS560702BA datasheet below including key specifications, electrical characteristics, absolute maximum ratings.
MS560702BA shares its datasheet with MS5607-02BA03, whose page lists every part number it covers.
Official MS560702BA datasheet (PDF) — the source this page was extracted from.
Manufacturer
MEAS SwitzerlandCategory
Pressure SensorsMS560702BA Key Specifications
| Parameter | Value |
|---|---|
| ESD Rating | 4 kV HBM |
| Interfaces | SPI (up to 20 MHz), I2C (up to 400 kHz) |
| Overpressure | 6 bar max |
| ADC Resolution | 24 bit |
| Pressure Range | 10 to 2000 mbar |
| Supply Current | 12.5 µA typ (OSR 4096, 1 sample/s) |
| Supply Voltage | 1.8V to 3.6V |
| Conversion Time | 0.54 ms to 8.22 ms typ (OSR 256 to 4096) |
| Standby Current | 0.02 µA typ (0.14 µA max) |
| Package Dimensions | 5.0 x 3.0 x 1.0 mm |
| Long Term Stability | ±1 mbar/yr |
| Pressure Resolution | 0.024 to 0.13 mbar RMS (OSR 4096 to 256) |
| Operating Temperature | -40°C to +85°C |
| Compensated Pressure Range | 300 to 1100 mbar |
| Temperature Accuracy (25°C) | ±0.8°C |
| Pressure Accuracy (25°C, 750 Mbar) | ±1.5 mbar |
MS560702BA Overview
Part: MS5607-02BA03 — MEAS Switzerland Type: Barometric Pressure Sensor Description: High resolution altimeter sensor with SPI and I2C bus interface, 24-bit ΔΣ ADC, optimized for altimeters and variometers with 20 cm altitude resolution, operating from 1.8 to 3.6 V.
Operating Conditions:
- Supply voltage: 1.8–3.6 V
- Operating temperature: -40 to +85 °C
- Pressure range: 10 to 2000 mbar
Absolute Maximum Ratings:
- Max supply voltage: 4 V
- Max storage temperature: 125 °C
- Overpressure: 6 bar
- Maximum Soldering Temperature: 250 °C (40 sec max)
Key Specs:
- Pressure range: 10 to 2000 mbar
- Pressure accuracy (25°C, 750 mbar): -1.5 to +1.5 mbar
- Temperature range: -40 to +85 °C
- Temperature accuracy (25°C): -0.8 to +0.8 °C
- ADC resolution: 24 bit
- Conversion time (OSR 4096): 7.40 to 9.04 ms
- Standby supply current (25°C): 0.02 μA (typ), 0.14 μA (max)
- SPI interface clock: up to 20 MHz
- I2C interface clock: up to 400 KHz
Features:
- Integrated digital pressure sensor (24 bit ΔΣ ADC)
- High resolution module, 20cm
- Fast conversion down to 1 ms
- Low power, 1 μA (standby < 0.15 μA)
- I2C and SPI interface up to 20 MHz
- No external components (Internal oscillator)
- Excellent long term stability
- Factory calibrated coefficients stored in PROM
Applications:
- Mobile altimeter / barometer systems
- Bike computers
- Variometers
- Dataloggers
- Mobile phones / GPS
Package:
- QFN 5.0 x 3.0 x 1.0 mm
MS560702BA Pin Configuration
| Pin | Name | Type | Function |
|---|---|---|---|
| 1 | VDD | P | Positive supply voltage |
| 2 | PS | I | Protocol select PS high (VDD) I 2 C PS low (GND) SPI |
| 3 | GND | G | Ground |
| 4 5 | CSB | I | Chip select (active low), internal connection |
| 6 | SDO | O | Serial data output |
| 7 | SDI / SDA | I / IO | Serial data input / I 2 C data IO |
| 8 | SCLK | I | Serial data clock |
MS560702BA Electrical Characteristics
| Parameter | Symbol | Conditions | Min. | Typ. | Max | Unit |
|---|---|---|---|---|---|---|
| Operating Supply voltage | V DD | 1.8 | 3.0 | 3.6 | V | |
| Operating Temperature | T | -40 | +25 | 85 | °C | |
| Supply current (1 sample per sec.) | I DD | OSR 4096 2048 1024 512 256 | 12.5 6.3 3.2 1.7 0.9 | μA | ||
| Peak supply current | during conversion | 1.4 | mA | |||
| Standby supply current | at 25°C | 0.02 | 0.14 | μA | ||
| VDD Capacitor | From VDD to GND | 100 | nF |
MS560702BA Absolute Maximum Ratings
| Parameter | Symbol | Conditions | Min. | Typ. | Max | Unit |
|---|---|---|---|---|---|---|
| Supply voltage | V DD | -0.3 | 4 | V | ||
| Storage temperature | T S | -40 | 125 | °C | ||
| Overpressure | P max | 6 | bar | |||
| Maximum Soldering Temperature | T max | 40 sec max | 250 | °C | ||
| ESD rating | Human Body Model | -4 | 4 | kV | ||
| Latch up | JEDEC standard No 78 | -100 | 100 | mA |
MS560702BA Typical Application
The MS5607-02BA is a circuit that can be used in conjunction with a microcontroller in mobile altimeter applications. It is designed for low-voltage systems with a supply voltage of 3 V.
Figure 17: Typical application circuit with SPI / I 2 C protocol communication
MS560702BA Package Information
Figure 18: MS5607-02BA03 package outline
Figure 18: MS5607-02BA03 package outline
Variants on the same datasheet
These parts have exact links to the same datasheet. They are candidates to compare, not verified drop-in replacements; check package, pinout and electrical limits.
| Part Number | Manufacturer | Package |
|---|---|---|
| MS5607 | MEAS Switzerland | QFN-8 5.0x3.0mm |
| MS5607-02BA | MEAS Switzerland | QFN-8 5.0x3.0mm |
| MS5607-02BA03 | MEAS Switzerland | QFN |
Other Pressure Sensors
- BMP390 – Bosch Sensortec, Digital pressure sensor
- LPS22HB – STMicroelectronics, MEMS Nano Pressure Sensor / Digital Output Barometer
- BMP388 – Bosch Sensortec, Digital pressure sensor
- DPS310 – Infineon Technologies, Digital Barometric Air Pressure Sensor
- LPS22HBTR – STMicroelectronics, MEMS Nano Pressure Sensor / Digital Output Barometer
- MS5607 – MEAS Switzerland, Barometric Pressure Sensor
- MS5607-02BA – MEAS Switzerland, Barometric Pressure Sensor
- MS5607-02BA03 – MEAS Switzerland, Barometric Pressure Sensor
All Pressure Sensors datasheetsAll MEAS Switzerland datasheets (4)
Ask your AI agent about the MS560702BA
Connect SheetsData to Claude, Cursor, Codex or any MCP client and your agent reads this datasheet for you: pinout, limits, register maps and design checks, with the numbers taken from the PDF.
claude mcp add --transport http sheetsdata https://mcp.sheetsdata.com/mcp
Then ask: "Can the MS560702BA run from my 12 V rail? Check it against the datasheet limits."
Create a free account $2 of usage every month, no card needed.