DPS310

Product Description

Manufacturer

Infineon Technologies

Category

Board Mount Pressure Sensors

Overview

Part: DPS310 Type: Digital Barometric Air Pressure Sensor

Key Specs:

  • Pressure operation range: 300 – 1200 hPa
  • Temperature operation range: -40 – 85 °C
  • Pressure sensor precision: ± 0.002 hPa
  • Relative accuracy: ± 0.06 hPa
  • Absolute accuracy: ± 1 hPa
  • Temperature accuracy: ± 0.5°C
  • Average current consumption (Pressure): 1.7 μA @1Hz sampling rate
  • Average current consumption (Temperature): 1.5 μA @1Hz sampling rate
  • Standby current consumption: 0.5 μA
  • Supply voltage VDDIO: 1.2 – 3.6 V
  • Supply voltage VDD: 1.7 – 3.6 V
  • Measurement time (standard mode): 27.6 ms
  • Measurement time (low precision mode): 3.6 ms

Features:

  • Capacitive sensing principle
  • 24-bit results for pressure and temperature
  • Individually calibrated with stored coefficients
  • Result FIFO stores up to 32 measurement results
  • Serial I2C or SPI interface (with optional interrupt)
  • Measurement status indicated by status bits or interrupts on SDO pin
  • Operating modes: Command (manual), Background (automatic), and Standby
  • Green Product (RoHS) Compliant

Applications:

  • Indoor Navigation (floor detection)
  • Health and Sports (accurate elevation gain and vertical speed)
  • Outdoor Navigation (GPS start-up time and accuracy improvement, dead-reckoning)
  • Weather Station ('Micro-weather' and local forecasts)
  • HDD drivers (leak rate detection)
  • Drones (flight stability and height control)

Package:

  • 8-pin LGA: 2.0 mm x 2.5 mm x 1.0 mm

Features

  • Operation range: Pressure: 300 –1200 hPa. Temperature: -40 85 °C.
  • Pressure sensor precision: ± 0.002 hPa (or ±0.02 m) (high precision mode).
  • Relative accuracy: ± 0.06 hPa (or ±0.5 m)
  • Absolute accuracy: ± 1 hPa (or ±8 m)
  • Temperature accuracy: ± 0.5°C.
  • Pressure temperature sensitivity: 0.5Pa/K
  • Measurement time: Typical: 27.6 ms for standard mode (16x). Minimum: 3.6 ms for low precision mode.
  • Average current consumption: 1.7 μA for Pressure Measurement, 1.5uA for Temperature measurement @1Hz sampling rate, Standby: 0.5 μA.
  • Supply voltage: VDDIO: 1.2 3.6 V, VDD: 1.7 3.6 V.
  • Operating modes: Command (manual), Background (automatic), and Standby.
  • Calibration: Individually calibrated with coefficients for measurement correction.
  • FIFO: Stores up to 32 pressure or temperature measurements.
  • Interface: I2C and SPI (both with optional interrupt)
  • Package dimensions: 8-pin LGA, 2.0 mm x 2.5 mm x 1.0 mm.
  • Green Product (RoHS) Compliant

Applications

  • Indoor Navigation (floor detection e.g. in shopping malls and parking garages)
  • Health and Sports (accurate elevation gain and vertical speed)
  • Outdoor Navigation (GPS start-up time and accuracy improvement, dead-reckoning e.g. in tunnels)
  • Weather Station('Micro-weather' and local forecasts)
  • HDD drivers, (leak rate detection in hard disk drives)
  • Drones (flight stability and height control)

Pin Configuration

2.1 Pin Configuration and Description

Figure 1 Pin configuration (top view, figure not to scale)

Table 2 Pin description

PinNameSPI 3-wireSPI 3-wire with
interrupt
SPI 4-wire2C
I
2C with
I
interrupt
1GNDGround
2CSBChip select - active
low
Chip select -
active low
Chip select -
active low
Not used - open
(internal pull-up)
or tie to VDDIO
Not used - open
(internal pull
up) or tie to
VDDIO
3SDISerial data in/outSerial data in/outSerial data inSerial data in/outSerial data
in/out
4SCKSerial Clock
5SDONot usedInterruptSerial data outLeast significant
bit in the device
address.
Interrupt pin
and least
significant bit in
the device
address.
6VDDIODigital supply voltage for digital blocks and I/O interface
7GNDGround
8VDDSupply voltage for analog blocks

Specifications

2.2 Block Diagram

Figure 2

Absolute Maximum Ratings

Maximum ratings are absolute ratings. Exceeding any one of these values may cause irreversible damage to the integrated circuit.

Attention: Stresses above the values listed as "Absolute Maximum Ratings" may cause permanent damage to the devices. Exposure to absolute maximum rating conditions for extended periods may affect device reliability.

Table 4 Absolute Maximum Ratings

ParameterSymbolValuesUnitNote / Test
Min.
Typ.
Max.
VDD and VDDIOVDDxx_max4V
Voltage on any pinVmax4V
Storage temperatureTs-40125°C
PressurePmax10,000hPa
ESDVESD_HBM-22KV
Data on this page is extracted from publicly available manufacturer datasheets using automated tools including AI. It may contain errors or omissions. Always verify specifications against the official manufacturer datasheet before making design or purchasing decisions. See our Terms of Service. Rights holders can submit a takedown request.