AH3722
Hall-effect latch ICThe AH3722 is a hall-effect latch ic from Diodes Incorporated. View the full AH3722 datasheet below including key specifications, electrical characteristics, absolute maximum ratings.
AH3722 shares its datasheet with AH3722-SA-7, whose page lists every part number it covers.
Official AH3722 datasheet (PDF) — the source this page was extracted from.
Manufacturer
Diodes IncorporatedCategory
SensorsAH3722 Key Specifications
| Parameter | Value |
|---|---|
| Current - Output (Max) | 55mA |
| Supply Current (Max) | 5mA |
| Features | Temperature Compensated |
| Function | Latch, Bipolar Switch |
| Mounting Type | Surface Mount |
| Operating Temperature | -40°C ~ 125°C |
| Output Type | Open Drain |
| Package / Case | TO-236-3, SC-59, SOT-23-3 |
| Polarization | North Pole, South Pole |
| Sensing Range | 4mT Trip, -4mT Release |
| Supplier Device Package | SOT-23 (Type S) |
| Diode Technology | Hall Effect |
| Test Condition | -40°C ~ 125°C |
| Supply Voltage | 3V ~ 28V |
AH3722 Overview
Part: AH372X — Diodes Incorporated
Type: High-voltage, high-sensitivity Hall-effect latch IC
Description: High-voltage, high-sensitivity Hall-effect latch IC designed for brushless DC-motor commutation, speed measurement, angular or linear encoders and position sensors, operating from 3.0V to 28V with a single open-drain output.
Operating Conditions:
- Supply voltage: 3.0 to 28 V
- Operating temperature: -40 to +125 °C
- Operation Point (BOP): 10 to 170 Gauss
- Release Point (BRP): -170 to -10 Gauss
Absolute Maximum Ratings:
- Max supply voltage: 32 V
- Max continuous current: 60 mA
- Max junction temperature: +150 °C
- Max storage temperature: -65 to +165 °C
Key Specs:
- Output On Voltage (V OUT_ON): 0.2 V (typ), 0.4 V (max) at I OUT = 20mA, B > B OP
- Output Leakage Current (I OUT_OFF): < 0.1 μA (typ), 10 μA (max) at V OUT = 28V, B < B RP
- Supply Current (I DD): 3 mA (typ), 5 mA (max) at output open, T A = -40°C to +125°C
- Device Startup Time (t ST): 10 μs (typ) at V DD ≥ 3V, B > B OP
- Output Current Limit (I OCL): 30 mA (min), 55 mA (max) at B > B OP
- Chopping Frequency (f C): 500 kHz (typ) at V DD ≥ 3V
- AH3722 Operation Point (B OP): 25 Gauss (typ)
- AH3722 Release Point (B RP): -25 Gauss (typ)
Features:
- Bipolar Latch (South Pole: On, North Pole: Off)
- 3.0V to 28V Operating Voltage Range
- High Sensitivity: BOP and BRP of 25G to 140G and -25G to -140G (typ)
- Single Open-Drain Output with Overcurrent Limit
- Chopper Stabilized Design Provides Superior Temperature Stability, Minimal Switch Point Drift, Enhanced Immunity to Stress, Good RF Noise Immunity
- Reverse Blocking Diode and Zener Clamp on Supply
- -40 °C to +125°C Operating Temperature
- High ESD HBM: 8kV
Applications:
- Brushless DC motor commutation
- Revolution per minute (RPM) measurement
- Flow meters
- Angular and linear encoders and position sensors
- Contactless commutation, speed measurement and angular position sensing/indexing in consumer home appliances, office equipment and industrial applications
Package:
- SC59
- SOT23 (Type S)
- SIP-3 (Ammo Pack)
- SIP-3 (Bulk Pack)
AH3722 Features
- Bipolar Latch (South Pole: On, North Pole: Off)
- 3.0V to 28V Operating Voltage Range
- High Sensitivity: BOP and BRP of 25G to 140G and -25G to -140G (typ)
- Single Open-Drain Output with Overcurrent Limit
- Chopper Stabilized Design Provides
- Superior Temperature Stability
- Minimal Switch Point Drift
- Enhanced Immunity to Stress
- Good RF Noise Immunity
- Reverse Blocking Diode and Zener Clamp on Supply
- -40 C to +125°C Operating Temperature
- High ESD HBM: 8kV
- Industry Standard SC59, SOT23 (Type S), SIP-3 (Ammo Pack) and SIP-3 (Bulk Pack) Packages
- Totally Lead-Free & Fully RoHS Compliant (Notes 1 & 2)
- Halogen and Antimony Free. 'Green' Device (Note 3 )
- For automotive applications requiring specific change control (i.e. parts qualified to AEC-Q100/101/104/200, PPAP capable, and manufactured in IATF 16949 certified facilities), please contact us or your local Diodes representative. https://www.diodes.com/quality/product-definitions/
- No purposely added lead. Fully EU Directive 2002/95/EC (RoHS), 2011/65/EU (RoHS 2) & 2015/863/EU (RoHS 3) compliant.
- See https://www.diodes.com/quality/lead-free/ for more information about Diodes Incorporated's definitions of Halogen- and Antimony-free, "Green" and Lead-free.
- Halogen- and Antimony-free "Green' products are defined as those which contain <900ppm bromine, <900ppm chlorine (<1500ppm total Br + Cl) and <1000ppm antimony compounds.
AH372X
HIGH-VOLTAGE HALL-EFFECT LATCH
AH3722 Applications
- Brushless DC motor commutation
- Revolution per minute (RPM) measurement
- Flow meters
- Angular and linear encoders and position sensors
- Contactless commutation, speed measurement and angular position sensing/indexing in consumer home appliances, office equipment and industrial applications
AH3722 Pin Configuration
SC59 and SOT23 (Type S)
SIP-3 (Ammo Pack) and SIP-3 (Bulk Pack)
AH3722 Electrical Characteristics
| Symbol | Parameter | Conditions | Min | Typ | Max | Unit |
|---|---|---|---|---|---|---|
| V OUT_ON | Output On Voltage | I OUT = 20mA, B > B OP | - | 0.2 | 0.4 | V |
| I OUT_OFF | Output Leakage Current | V OUT = 28V, B < B RP , output off | - | < 0.1 | 10 | μA |
| Output open, T A = +25 C | - | 3 | 4 | mA | ||
| I DD | Supply Current | Output open, T A = -40°C to +125°C | - | - | 5 | mA |
| V DD = -18V, T A = -40°C to +125°C | -0.01 | 1 | mA | |||
| t ST | Device Startup Time | V DD ≥ 3V, B > B OP (Note 7) | - | 10 | - | μs |
| f C | Chopping Frequency | V DD ≥ 3V | - | 500 | - | kHz |
| t D | The Time Delay from Magnetic Threshold Reached to the Start of the Output Rise or Fall | (Note 9) | - | 4 | - | μs |
| t R | Output Rising Time (External Pullup Resistor R L and Load Capacitance Dependent) | R L = 1kΩ, C L = 20pF (Note 9) | - | 0.2 | 1 | μs |
| t F | Output Falling Time (Internal Switch Resistance and Load Capacitance Dependent) | R L = 1kΩ, C L = 20pF (Note 9) | - | 0.1 | 1 | μs |
| I OCL | Output Current Limit | B > B OP (Note 10 ) | 30 | - | 55 | mA |
| V Z | Zener Clamp Voltage | I DD = 5mA, T A = +25°C | 28 | - | - | V |
-
When power is initially turned on, VDD must be within its correct operating range (3.0V to 28V) to guarantee the output sampling. The output state is valid after the startup time of 10μs typical from the operating voltage reaching 3V.
-
Typical values are defined at TA = +25 C, VDD = 12V. Maximum and minimum values over the operating temperature range is not tested in production but guaranteed by design, process control and characterization.
-
Guaranteed by design, process control, and characterization. Not tested in production.
-
The device limits the output current IOUT to current limit of IOCL.
AH372X
AH372X
AH3722 Absolute Maximum Ratings
| Symbol | Characteristic | Characteristic | Value | Unit |
|---|---|---|---|---|
| V DD | Supply Voltage (Note 6) | Supply Voltage (Note 6) | 32 | V |
| V DDR | Reverse Supply Voltage | Reverse Supply Voltage | -18 | V |
| V OUT_MAX | Output Pin Off Voltage (Note 6) | Output Pin Off Voltage (Note 6) | 32V | V |
| I OUT | Continuous Output Current | Continuous Output Current | 60 | mA |
| I OUT_R | Reverse Output Current | Reverse Output Current | -50 | mA |
| B | Magnetic Flux Density | Magnetic Flux Density | Unlimited | Unlimited |
| P D | Package Power Dissipation | SIP-3 (Ammo Pack) SIP-3 (Bulk Pack) | 550 | mW |
| P D | Package Power Dissipation | SC59 and SOT23 (Type S) | 230 | mW |
| T S | Storage Temperature Range | Storage Temperature Range | -65 to +165 | °C |
| T J | Maximum Junction Temperature | Maximum Junction Temperature | +150 | °C |
| ESD HBM | Electrostatic Discharge Withstand Capability-Human Body Model | Electrostatic Discharge Withstand Capability-Human Body Model | 8 | kV |
-
Stresses greater than those listed under Absolute Maximum Ratings can cause permanent damage to the device. These are stress ratings only, and functional operation of the device at these or any other conditions beyond those indicated under Recommended Operating Conditions is not implied. Exposure to Absolute Maximum Ratings for extended periods can affect device reliability.
-
The absolute maximum VDD of 32V is a transient stress rating and is not meant as a functional operating condition. It is not recommended to operate the device at the absolute maximum-rated conditions for any period of time.
AH3722 Recommended Operating Conditions
| Symbol | Parameter | Conditions | Rating | Unit |
|---|---|---|---|---|
| V DD | Supply Voltage | Supply voltage, between V DD and GND pins | 3.0 to 28 | V |
| T A | Operating Temperature Range | Operating ambient temperature range | -40 to +125 | °C |
AH3722 Typical Application
Note: 4. CIN is for power stabilization and to strengthen the noise immunity. The recommended capacitance is 10nF to 100nF. RL is the pullup resistor.
AH3722 Package Information
Please see http://www.diodes.com/package-outlines.html for the latest version.
Variants on the same datasheet
These parts have exact links to the same datasheet. They are candidates to compare, not verified drop-in replacements; check package, pinout and electrical limits.
| Part Number | Manufacturer | Package |
|---|---|---|
| AH3722-P-A | Diodes Incorporated | SIP-3 |
| AH3722-P-B | Diodes Incorporated | SIP-3 |
| AH3722-SA-7 | Diodes Incorporated | TO-236-3, SC-59, SOT-23-3 |
| AH3722-W-7 | Diodes Incorporated | TO-236-3, SC-59, SOT-23-3 |
| AH3724 | Diodes Incorporated | — |
| AH3725 | Diodes Incorporated | — |
| AH3727 | Diodes Incorporated | SIP-3 |
Other Sensors
- ICM-20948 – TDK InvenSense, 9-axis MotionTracking device
- MPU-6050 – TDK InvenSense, 6-Axis MEMS IMU
- MAX30102 – Analog Devices, Pulse Oximetry and Heart-Rate Monitor Module
- MPU-9250 – TDK InvenSense, 9-Axis MotionTracking IMU
- ZMPT101B – Zmpt, Voltage Sensor Module
- AD5941 – Analog Devices, High Precision, Impedance, and Electrochemical Front End
- AH3722-P-A – Diodes Incorporated, Hall-effect latch IC
- AH3722-P-B – Diodes Incorporated, Hall-effect latch IC
Ask your AI agent about the AH3722
Connect SheetsData to Claude, Cursor, Codex or any MCP client and your agent reads this datasheet for you: pinout, limits, register maps and design checks, with the numbers taken from the PDF.
claude mcp add --transport http sheetsdata https://mcp.sheetsdata.com/mcp
Then ask: "Can the AH3722 run from my 12 V rail? Check it against the datasheet limits."
Create a free account $2 of usage every month, no card needed.