7448025003
Common Mode Power Line ChokeThe 7448025003 is a common mode power line choke from Würth Elektronik. View the full 7448025003 datasheet below including key specifications.
Manufacturer
Würth Elektronik
Category
Common Mode Power Line Choke
Package
Vertical, 4 PC Pin
Lifecycle
Active
Key Specifications
| Parameter | Value |
|---|---|
| Ambient Temperature Range High | 60 °C |
| Ambient Temperature Range Low | -40 °C |
| Current Rating | 5 A |
| Current Rating (Max) | 5A |
| DC Resistance (DCR) (Max) | 15mOhm |
| Features | Nanocrystalline Core |
| Filter Type | Power Line |
| Height | 22 mm |
| Height (Max) | 0.866" (22.00mm) |
| Inductance | 2.5 mH |
| Inductance @ Frequency | 2.5 mH @ 10 kHz |
| Length | 18 mm |
| Max Operating Temperature | 125 °C |
| Min Operating Temperature | -55 °C |
| Mounting Type | Through Hole |
| Number of Lines | 2 |
| Operating Temperature | -40°C ~ 125°C |
| Package / Case | Vertical, 4 PC Pin |
| RMS Current (Irms) | 5 A |
| RoHS | Compliant |
| Series Resistance | 15 mΩ |
| Size / Dimension | 0.709" L x 0.551" W (18.00mm x 14.00mm) |
| Test Frequency | 10 kHz |
| Voltage Rating | 250 V |
| Voltage Rating - AC | 250V |
| Width | 14 mm |
Overview
Part: 7448025003 — Würth Elektronik eiSos
Type: Common Mode Power Line Choke
Description: 2-winding nanocrystalline common mode power line choke with 2.5 mH inductance, 5 A rated current, and 250 V (AC) rated voltage.
Operating Conditions:
- Max rated voltage: 250 V (AC)
Key Specs:
- Inductance (L): 2.5 mH (+50%/-30%) at 10 kHz/0.1 mA
- Rated Current (I R): 5 A max. at 70 °C
- DC Resistance (R DC): 15 mΩ max. at 20 °C
- Rated Voltage (V R): 250 V (AC) max. at 50 Hz
- Insulation Test Voltage (V T): 1500 V (AC) at 50 Hz/5 mA/2 sec.
- Number of windings: 2
Features:
- RoHS Compliant [2011/65/EU&2015/863]
- REACh Conform or declared [(EC)1907/2006]
- ENEC 10 Approval (40048238)
- VDE Approval (40048238)
- Nanocrystalline core
Applications:
- General electronic equipment (not authorized for use in equipment requiring higher safety/reliability standards or where failure could cause severe personal injury/death, or in military, aerospace, medical, etc. applications without prior agreement)
Package:
- Type S
Applications
It has to be clearly pointed out that the possibility of a malfunction of electronic components or failure before the end of the usual lifetime cannot be completely eliminated in the current state of the art, even if the products are operated within the range of the specifications. In certain customer applications requiring a very high level of safety and especially in customer applications in which the malfunction or failure of an electronic component could endanger human life or health it must be ensured by most advanced technological aid of suitable design of the customer application that no injury or damage is caused to third parties in the event of malfunction or failure of an electronic component. Therefore, customer is cautioned to verify that data sheets are current before placing orders. The current data sheets can be downloaded at www.we-online.com.
Get structured datasheet data via API