SGX-4NH3-1000
Electrochemical Ammonia (NH3) Gas SensorThe SGX-4NH3-1000 is a electrochemical ammonia (nh3) gas sensor from SGX Sensortech. View the full SGX-4NH3-1000 datasheet below including key specifications, pinout.
Official SGX-4NH3-1000 datasheet (PDF) — the source this page was extracted from.
Manufacturer
SGX Sensortech
Category
Electrochemical Ammonia (NH3) Gas Sensor
Lifecycle
Active
SGX-4NH3-1000 Key Specifications
| Parameter | Value |
|---|---|
| Quiescent Current | 300µA |
| Operating Temperature | -40°C ~ 50°C |
| Output | Current |
| Oxygen Range | 800 mbar ~ 1200 mbar |
| Part Series | 4 |
| Standard Pack Qty | 1 |
| Type | Ammonia (NH3) |
SGX-4NH3-1000 Overview
Part: SGX-4NH3-1000 — SGX Sensortech
Type: Electrochemical Ammonia (NH3) Gas Sensor
Description: Industrial electrochemical NH3 sensor with 0–1000 ppm measurement range, 8 ± 4 nA/ppm output signal and T90 response time under 75 seconds.
Operating Conditions:
- Supply voltage: not applicable (electrochemical sensor, current output)
- Operating temperature: -40 to +50 °C
- Pressure range: 800 to 1200 mbar
- Operating humidity range: 15% to 90% RH
Absolute Maximum Ratings:
- Maximum overload: 1500 ppm
- Recommended storage temperature: 0 to 20 °C
Key Specs:
- Output signal: 8 ± 4 nA/ppm
- Typical baseline range (pure air): ± 10 ppm NH3 equivalent
- T90 response time: < 75 seconds
- Measurement range: 0–1000 ppm, linear
- Repeatability: ± 10%
- Recommended load resistor: 10 Ω
- Resolution (electronics dependent): 5 ppm
- Long-term output drift: < 20% per annum
- Expected operating life: > 24 months in air
Features:
- Linear output over 0–1000 ppm
- Intrinsic safety data provided (max at 2000 ppm: 0.3 mA; max open-circuit voltage 1.3 V; max short-circuit current < 1.0 A)
- Designed to be RoHS compliant
- Cross-sensitivity data provided for CO, H2S, SO2, NO, NO2, H2, ethanol and CO2
Applications:
- Industrial ammonia gas detection
Package:
- Electrochemical sensor with connector pins (use PSB sockets; do not solder or glue pins)
SGX-4NH3-1000 Pin Configuration
Package: 3-pin electrochemical gas sensor (3 × Ø1.55 mm pins on 13.5 mm PCD)
| Pin Number | Pin Name | Type | Description |
|---|---|---|---|
| ? | Working | S | Working electrode |
| ? | Reference | S | Reference electrode |
| ? | Counter | S | Counter electrode |
Notes
- The pin diagram shows three pins (Working, Reference, Counter) but does not print numeric pin numbers, so pin numbering could not be determined from the source material. Pin Number is shown as "?" for every row.
- The text tables provide no pin-level data for SGX-4NH3-1000; pin names are taken from the pin diagram labels.
- Pin 2D/3D geometry: pins are Ø1.55 mm on a 13.5 mm pitch circle, sensor body height 16.50 mm, pin length below body 3.90 mm.
- Do not glue or solder to the connector pins; use PSB sockets (per datasheet note 1).
SGX-4NH3-1000 Ordering Information
No ordering table was found in this datasheet section. The section contains no ordering codes, part-number variants, or package options for SGX-4NH3-1000 or any related part. The only product identifiers present are the device name "SGX-4NH3-1000" (heading) and "SGX-NH3-1000" (cross-sensitivity table header); no packaging or packing information is given.
| MPN | Package | Temperature Range | Packing |
|---|---|---|---|
| — | — | — | — |
Ask your AI agent about the SGX-4NH3-1000
Connect SheetsData to Claude, Cursor, Codex or any MCP client and your agent reads this datasheet for you: pinout, limits, register maps and design checks, with the numbers taken from the PDF.
claude mcp add --transport http sheetsdata https://mcp.sheetsdata.com/mcp
Then ask: "Can the SGX-4NH3-1000 run from my 12 V rail? Check it against the datasheet limits."
Create a free account $2 of usage every month, no card needed.