SG300Q
Gas Discharge TubeThe SG300Q is a gas discharge tube from Littelfuse. View the full SG300Q datasheet below including key specifications, electrical characteristics.
SG300Q shares its datasheet with SG90, whose page lists every part number it covers.
Official SG300Q datasheet (PDF) — the source this page was extracted from.
Manufacturer
LittelfuseCategory
Gas Discharge Tube
SG300Q Key Specifications
| Parameter | Value |
|---|---|
| DC breakdown voltage (100 V/s, 25 °C) | 63 V min / 90 V typ / 117 V max |
| Impulse breakdown voltage (100 V/μs) | 500 V max |
| Impulse breakdown voltage (1 kV/μs) | 600 V |
| Insulation resistance | >1 GΩ (at 50 VDC) |
| Arc voltage (at 1 A) | ~10 V |
| Glow-to-arc transition current | ~1.0 A |
| Glow voltage | ~60 V |
| Nominal AC discharge current (10× at 50 Hz) | 2 A |
| Nominal impulse discharge current (10× at 8/20 μs) | 2 kA |
| Typical insertion loss | 0.01 dB at 1.0 GHz, 1 dB at 2.45 GHz, 2.1 dB at 3.5 GHz |
SG300Q Overview
Part: SG90 (SG Series GDT) — Littelfuse
Type: Gas Discharge Tube (2-electrode surface-mount surge protector)
Description: 90 V nominal DC breakdown (63–117 V at 100 V/s), 2 kA (8/20 μs) surge-rated, miniature 4.5×3.2×2.7 mm surface-mount gas discharge tube with low capacitance (<1 pF series characteristic).
Operating Conditions:
- Supply voltage: not applicable
- Storage and operational temperature: -40 to +90 °C
- Nominal DC breakdown voltage: 90 V typ. (at 25 °C, 100 V/s)
Absolute Maximum Ratings:
- Storage temperature: -40 to +90 °C
- Reflow peak temperature: do not exceed 260 °C
Key Specs:
- DC breakdown voltage (100 V/s, 25 °C): 63 V min / 90 V typ / 117 V max
- Impulse breakdown voltage (100 V/μs): 500 V max
- Impulse breakdown voltage (1 kV/μs): 600 V
- Insulation resistance: >1 GΩ (at 50 VDC)
- Arc voltage (at 1 A): ~10 V
- Glow-to-arc transition current: ~1.0 A
- Glow voltage: ~60 V
- Nominal AC discharge current (10× at 50 Hz): 2 A
- Nominal impulse discharge current (10× at 8/20 μs): 2 kA
- Typical insertion loss: 0.01 dB at 1.0 GHz, 1 dB at 2.45 GHz, 2.1 dB at 3.5 GHz
Features:
- RoHS compliant and lead-free
- GHz working frequency
- Ultra-low insertion loss
- Low capacitance (<1 pF), not varying with voltage; suitable for ADSL2+
- Excellent response to fast rising transients
- Excellent stability on multiple pulse duty cycles
- Surge capability tested with 8/20 μs pulse per IEC 61000-4-5
- Conforms to ITU-T K12 and IEC 61000-4-5
- UL recognized (file E128662)
- Non-radioactive
Applications:
- Communication equipment
- CATV and satellite equipment
- Test equipment
- Data lines
- Power supplies
- Telecom SLIC protection
- Broadband, ADSL, ADSL2+ and xDSL equipment
- General telecom equipment
Package:
- Surface-mount square-outline GDT, 4.5×3.2×2.7 mm
- Tape and reel, 2000 pcs/reel (IEC 60286-3)
SG300Q Features
- RoHS compliant and Lead-free
- GHz working frequency
- Excellent stability on multiple pulse duty cycle
- Excellent response to fast rising transients.
- Ultra Low Insertion Loss
- 1-2KA surge capability tested with 8/20μS pulse as defined by IEC 61000-4-5
SG300Q Applications
- Communication equipment
- CATV equipment
- Test equipment
- Data lines
- Power supplies
- Telecom SLIC protection
- Ultra small devices offered in a variety of mounting lead forms
- Non-Radioactive
- Low capacitance (<1pF)
- Voltage Ranges 75V to 600V
- UL Recongized
- Conforms to ITU-T K12, IEC 61000-4-5
- Square Outline
- Broadband equipment
- ADSL equipment, including ADSL2+
- XDSL equipment
- Satellite and CATV equipment
- General telecom equipment
SG300Q Electrical Characteristics
| Part Number | Device Specifications (at 25°C) - DC Breakdown inVolts (@100V/s) - Min. | Device Specifications (at 25°C) - DC Breakdown inVolts (@100V/s) - Typ. | Device Specifications (at 25°C) - DC Breakdown inVolts (@100V/s) - Max. | Device Specifications (at 25°C) - Impulse Breakdown inVolts (@100V/μs) - Max. | Device Specifications (at 25°C) - Impulse Breakdown InVolts (@1 Kv/ μsec) | Device Specifications (at 25°C) - Insulation Resistance - Min. | Device Specifications (at 25°C) - Capaci- tance (@1MHz) - Max. | Device Specifications (at 25°C) - Arc Voltage (@1A) | Device Specifications (at 25°C) - Glow to Arc Transition Current | Device Specifications (at 25°C) - Glow Voltage | Life Ratings - NominalAC Discharge Current (x10 @50Hz) | Life Ratings - Nominal Impulse Discharge Current (x10 @8/20μs) | Life Ratings - Nominal Impulse Discharge Current (10/1000μs 100 cycles) |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| SG75 | 52 | 75 | 98 | 500 | 650 | >1GΩ (at 50VDC) >1GΩ | ~10 V | ~1.0 A | ~60 V | 2 A | 2kA | ||
| SG90 | 63 | 90 | 117 | 500 | 600 | >1GΩ (at 50VDC) >1GΩ | ~10 V | ~1.0 A | ~60 V | 2 A | 2kA | ||
| SG150 | 105 | 150 | 195 | 500 | 600 | >1GΩ (at 50VDC) >1GΩ | ~10 V | ~1.0 A | ~60 V | 2 A | 2kA | ||
| SG200 + | 140 | 200 | 260 | 550 | 700 | (at 100VDC) | <1 pf | ~10 V | ~1.0 A | ~60 V | 2.5 A | 1kA | |
| SG230 | 172 | 230 | 288 | 650 | 800 | >1GΩ (at 50VDC) >1GΩ | ~10 V | ~1.0 A | ~60 V | 2 A | 1kA | ||
| SG300 | 225 | 300 | 375 | 700 | 850 | >1GΩ (at 50VDC) >1GΩ | ~12 V | ~0.5 A | ~90 V | 2 A | 1kA | ||
| SG300Q | 210 | 300 | 390 | 580 | 650 | >1GΩ (at 50VDC) >1GΩ | ~20 V | ~0.8 A | ~140 V | NA* | 1kA | ||
| SG350 | 263 | 350 | 437 | 750 | 900 | >1GΩ (at | ~20 V | ~0.8 A | ~90 V | 2 A | 1kA | ||
| SG350Q | 263 | 350 | 437 | 600 | 700 | 50VDC) | <0.8 pf | ~12 V | ~0.5 A | ~140 V | NA* | 1kA | |
| SG400 | 300 | 400 | 500 | 800 | 950 | >1GΩ (at 50VDC) >1GΩ | ~20 V | ~0.8 A | ~90 V | 2 A | 1kA | ||
| SG420 | 315 | 420 | 525 | 800 | 1000 | >1GΩ (at 50VDC) >1GΩ | <1 pf | ~10 V | <1.0 A | ~60 V | 2 A | 1kA | |
| SG420Q | 315 | 420 | 525 | 650 | 750 | >1GΩ (at 50VDC) >1GΩ | <1 pf | ~20 V | <1.0 A | NA* | 1kA | ||
| SG450Q | 370 | 450 | 500 | 680 | 750 | >1GΩ (at 50VDC) >1GΩ | <1 pf | ~20 V | <1.0 A | ~140 V | 1 A | 1kA | |
| SG500Q | 400 | 500 | 600 | 950 | 1050 | >1GΩ (at 100VDC) | <0.5 pf | ~16 V | ~0.1 A | 2 A | 1kA | ||
| SG600Q | 450 | 600 | 750 | 1100 | 1200 | >1GΩ (at 50VDC) >1GΩ | <1 pf | ~20 V | <0.5 A | 2 A | 1kA |
Variants on the same datasheet
These parts have exact links to the same datasheet. They are candidates to compare, not verified drop-in replacements; check package, pinout and electrical limits.
More datasheets
Ask your AI agent about the SG300Q
Connect SheetsData to Claude, Cursor, Codex or any MCP client and your agent reads this datasheet for you: pinout, limits, register maps and design checks, with the numbers taken from the PDF.
claude mcp add --transport http sheetsdata https://mcp.sheetsdata.com/mcp
Then ask: "Can the SG300Q run from my 12 V rail? Check it against the datasheet limits."
Create a free account $2 of usage every month, no card needed.