RC1210FR-073R3L
RF Transceiver ModuleThe RC1210FR-073R3L is a rf transceiver module from Radiocrafts. View the full RC1210FR-073R3L datasheet below including key specifications, electrical characteristics, absolute maximum ratings.
Official RC1210FR-073R3L datasheet (PDF) — the source this page was extracted from.
Manufacturer
Radiocrafts
Category
RF Transceiver Module
Package
SMD Module (12.7 x 25.4 x 3.7 mm)
RC1210FR-073R3L Key Specifications
| Parameter | Value |
|---|---|
| Frequency band | 418.725–419.450 MHz, 30 channels |
| Max output power | 8 dBm |
| Sensitivity | -112 dBm |
| Current consumption RX | 20.2 mA |
| Current consumption TX | 26 mA |
| Current consumption SLEEP | 0.9 mA |
| Current consumption OFF | 0.003 μA (3 nA) |
| Line-of-sight range | 1–2 km with quarter-wave antennas |
| Internal regulated VDD | 2.7 V (logic swing 0–2.7 V on some pins) |
RC1210FR-073R3L Overview
Part: RC1210 (RC1210FR-073R3L) — Radiocrafts
Type: Narrow Band Multi-Channel RF Transceiver Module
Description: 418.725–419.450 MHz, 25 kHz narrow band FSK transceiver module with embedded RC232 protocol, 30 channels, up to 8 dBm output power, -112 dBm sensitivity and a 2.8–5.5 V supply range.
Operating Conditions:
- Supply voltage: 2.8–5.5 V
- Operating temperature: -20 to 55 °C
- Data rate: 4.8 kbit/s; channel bandwidth 25 kHz
- UART default settings: 19200, 8, 1, N
Absolute Maximum Ratings:
- Max supply voltage (VCC): 5.5 V
- Voltage on any pin: -0.3 to 5.5 V
- Input RF level: 10 dBm
- Storage temperature: -50 to 150 °C
Key Specs:
- Frequency band: 418.725–419.450 MHz, 30 channels
- Max output power: 8 dBm
- Sensitivity: -112 dBm
- Current consumption RX: 20.2 mA
- Current consumption TX: 26 mA
- Current consumption SLEEP: 0.9 mA
- Current consumption OFF: 0.003 μA (3 nA)
- Line-of-sight range: 1–2 km with quarter-wave antennas
- Internal regulated VDD: 2.7 V (logic swing 0–2.7 V on some pins)
Features:
- Smallest in the world (12.7 x 25.4 x 3.7 mm)
- 25 kHz narrow band multi-channel operation
- Embedded RC232 protocol with addressing and error check
- 128 byte data buffer
- Simple UART interface for RS232/422/485 wire replacement
- Synchronous un-buffered transparent mode (SCL/SDA)
- Shielded SMD module, no external components
- No configuration required for single-channel use
- 3/5 V tolerant I/O
- Conforms with Chinese license-free band regulations (pre-certified)
Applications:
- OEM equipment
- Radio modems
- Alarm and security systems
- Point-of-sales terminals
- Bar code scanners
- Telemetry stations
- Fleet management
Package:
- Shielded SMD module, 12.7 x 25.4 x 3.7 mm
RC1210FR-073R3L Features
- Smallest in the world (12.7 x 25.4 x 3.7 mm)
- 25 kHz narrow band multi-channel operation
- Very low current consumption, 3nA OFF mode
- Embedded RC232™ protocol
- Addressing and Error check
- 128 byte data buffer
- Simple UART interface for easy RS232/422/485 wire replacement
- Compact shielded module for SMD mounting
- No external components
- No configuration required for single-channel use
- Easy to use data interface, 3/5 V tolerant I/O
- Wide supply voltage range, 2.8 - 5.5 V
- Conforms with the Chinese regulations for license-free bands (Regulation for low power (short range) devices, Ministry of Information Industry May 1998)
RC1210FR-073R3L Applications
- OEM equipment
- Radio modems
- Alarm and security systems
- Point-of-sales terminals
- Bar code scanners
- Telemetry stations
- Fleet management
RC1210FR-073R3L Pin Configuration
| Pin no | Pin name | Description | Equivalent |
|---|---|---|---|
| 1 | GND | System ground | circuit GND 100k Input: VDD (2.7V) VDD (2.7V) Output: |
| 2 | CTS/RXTX/RXEN | UART Clear to Send, UART RXTX, Receive Mode Enable, or SLEEP mode activation. Connect to VDD if not used. Internal 100 kΩ series resistor. | circuit GND 100k Input: VDD (2.7V) VDD (2.7V) Output: |
| 3 | RTS/TXEN | UART Request to Send, Transmit Mode Enable, or SLEEP mode activation. Connect to VDD if not used. Internal 100 kΩ series resistor. | circuit GND 100k Input: VDD (2.7V) VDD (2.7V) Output: |
| 4 | CONFIG | Configuration Enable. Active low. Should normally be set high. Connect to VDD if not used. Internal 100 kΩ series resistor. | circuit GND 100k Input: VDD (2.7V) VDD (2.7V) Output: |
| 5 | TXD/SCL | UART TX Data, or serial data clock. Internal 100 kΩ series resistor. | circuit GND 100k Input: VDD (2.7V) VDD (2.7V) Output: |
| 6 | RXD/SDA | UART RX Data, or serial data I/O. Internal 100 kΩ series resistor. | circuit GND 100k Input: VDD (2.7V) VDD (2.7V) Output: |
| 7 | GND | System ground | GND 220p 10k |
| 8 | GND | System ground | GND 220p 10k |
| 9 | RF | RF I/O connection to antenna | |
| 10 | GND | System ground | GND |
| 11 | VDD | Supply voltage output, regulated. Should normally be left open | 2.7 V VREG 2.7 V VREG 2u2 VDD |
| 12 | ON/OFF | Module on/off (shutdown). ON when high, OFF when low. For threshold see Electrical Specifications. Or connect to VCC. See important note under Power Management page 7. | ON/OFF |
| 13 | VCC | Supply voltage input. Internally regulated. Maximum rise-time requirement apply, see Electrical Specification. | 2.7 V VREG 2.7 V VREG 2u2 VCC |
| 14 | GND | System ground | GND |
| 15-21 | RESERVED | Test pins or pins reserved for future use. Do not connect! | |
| 22 | RESET | Main reset (active low). Should normally be left open. Internal 100 kΩ pull-up resistor, no series resistor. | VDD (2.7V) RESET 100k |
| 23 | PA_EN | External PA enable output, active high | VDD (2.7V) |
| 24 | LNA_EN | External LNA enable output, active high | |
| 25-30 | RESERVED | Test pins or pins reserved for future use. Do not connect! |
Note 1: In UART mode the TXD and RXD are used for serial data, and CTS/RXTX and RTS for flow control (optional). If flow control is not used, and RXEN and TXEN are both asserted (active low) the module is set in SLEEP mode. RXEN and TXEN should be connected to VDD if not used if not used for SLEEP mode activation. A pull-up resistor is not necessary due to an internal series resistor.
Note 2: In synchronous mode the SCL (data clock) and SDA (Data input and output) are used for serial data. The RXEN and TXEN pins are then used to select the operation mode of the device. Signals are active low.
Note 3: The CONFIG pin is used to enter configuration mode (change of default settings). Active low.
Note 4: Do not use VDD for supply to external circuits. Should only be used for pull-ups, if required.
Note 5: RXEN, TXEN, CONFIG, TXD and RXD have internal 100 kΩ series resistors. Driving capability when used as outputs is therefore limited and should be connected to CMOS inputs only.
Note 6: Other digital interfaces may be specified upon request.
RC1210FR-073R3L Electrical Characteristics
T=25 C, VCC = 3.0V if nothing else stated.
| Parameter | Min | Typ. | Max | Unit | Condition / Note |
|---|---|---|---|---|---|
| Operating frequency | 418.725 | 419.450 | MHz | ||
| Number of channels | 30 | ||||
| Channel spacing | 25 | kHz | |||
| Input/output impedance | 50 | Ohm | |||
| Data rate | 4.8 | kbit/s | |||
| Frequency stability | +/-2.5 | ppm | |||
| Transmit power | -20 | 8 | 10 | dBm | Typical values are for default settings |
| FSK deviation | +/- 2.4 | kHz | |||
| Adjacent channel power | -55 | -45 | dBc | ||
| Occupied bandwidth | 14 | 16 | kHz | 99.5% | |
| Spurious emission, TX | 2.5 | μW | Equals -26 dBm | ||
| Sensitivity | -112 | dBm | |||
| Adjacent channel rejection | 30 | dB | |||
| Alternate channel selectivity | 40 | dB | |||
| Image channel rejection | 40 | dB | |||
| Blocking / Interferer rejection / desensitization +/- 1 MHz +/- 2 MHz +/- 5 MHz +/- 10 MHz | 40 40 50 60 | 60 60 70 75 | dB | Wanted signal 3 dB above sensitivity level, CW interferer. Minimum numbers corresponds to class 2 receiver requirements in EN300220. | |
| Saturation | 10 | dBm | |||
| Input IP3 | -18 | dBm | |||
| Spurious emission, RX | -57 | dBm | |||
| Supply voltage | 2.8 | 5.5 | V | ||
| Parameter | Min | Typ. | Max | Unit | Condition / Note |
| Supply voltage rise time | 150 | us | If appropriate rise time can not be guaranteed, the RESET pin should be activated after supply voltage is stable. | ||
| Current consumption, RX/IDLE | 20.2 | mA | Apply over entire supply voltage range | ||
| Current consumption, TX | 26 | mA | Apply over entire supply voltage range | ||
| Current consumption, SLEEP | 0.9 | 1.5 | mA | Max value in bold apply over the entire temperature and supply voltage range | |
| Current consumption, OFF | 0.003 | 1.5 | μA | Max value in bold apply over the entire temperature and supply voltage range | |
| Digital I/O Input logic level, low Input logic level, high Output logic level, low (1μA) Output logic level, high(-1μA) | 1.7 0 2.6 | 0.7 5.5 0.1 2.7 | V | RXEN, TXEN, CONFIG, TXD and RXD have internal 100 kΩ series resistors. No internal pull-ups. Outputs should not be loaded resistively. | |
| RESET pin Input logic level, low Input logic level, high | 1.7 | 0.7 2.7 | V | Internal 100 kΩ pull-up resistor to VDD | |
| ON/OFF pin Input logic level, low Input logic level, high | 1.4 | 0.4 VCC | V | No internal pull-up resistor | |
| UART Baud Rate tolerance | +/- 2 | % | UART receiver and transmitter | ||
| Configuration memory write cycles | 10 000 | 100 000 | The guaranteed number of write cycles using the 'M' command is limited |
RC1210FR-073R3L Absolute Maximum Ratings
| Parameter | Min | Max | Unit |
|---|---|---|---|
| Supply voltage, VCC | -0.3 | 5.5 | V |
| Voltage on any pin | -0.3 | 5.5 | V |
| Input RF level | 10 | dBm | |
| Storage temperature | -50 | 150 | C |
| Operating temperature | -20 | 55 | C |
Caution ! ESD sensitive device. Precaution should be used when handling the device in order to prevent permanent damage.
Under no circumstances the absolute maximum ratings given above should be violated. Stress exceeding one or more of the limiting values may cause permanent damage to the device.
RC1210FR-073R3L Typical Application
Variants on the same datasheet
These parts have exact links to the same datasheet. They are candidates to compare, not verified drop-in replacements; check package, pinout and electrical limits.
| Part Number | Manufacturer | Package |
|---|---|---|
| RC1210 | YAGEO | — |
| RC1210FR-071ML | YAGEO | 1210 (3225 Metric) |
Ask your AI agent about the RC1210FR-073R3L
Connect SheetsData to Claude, Cursor, Codex or any MCP client and your agent reads this datasheet for you: pinout, limits, register maps and design checks, with the numbers taken from the PDF.
claude mcp add --transport http sheetsdata https://mcp.sheetsdata.com/mcp
Then ask: "Can the RC1210FR-073R3L run from my 12 V rail? Check it against the datasheet limits."
Create a free account $2 of usage every month, no card needed.