Skip to main content

We use cookies to understand how you use our site and improve your experience. See our Privacy Policy.

MAX-M10M-00B-01

Standard precision GNSS module

The MAX-M10M-00B-01 is a standard precision gnss module from u-blox. View the full MAX-M10M-00B-01 datasheet below including key specifications, electrical characteristics, absolute maximum ratings.

MAX-M10M-00B-01 shares its datasheet with MAX-M10M-00B, whose page lists every part number it covers.

Official MAX-M10M-00B-01 datasheet (PDF) — the source this page was extracted from.

Manufacturer

u-blox

Category

Standard precision GNSS module

Package

LCC-18 9.7x10.1mm

MAX-M10M-00B-01 Key Specifications

ParameterValue
Antenna ConnectorNot Included
ApplicationsGPS Receiver
Data InterfaceI2C, UART
Modulation or ProtocolBeiDou, Galileo, GLONASS, GNSS, GPS
Mounting TypeSurface Mount
Operating Temperature-40°C ~ 85°C
Package / Case18-SMD Module
Sensitivity-164dBm
Supply Voltage1.8V ~ 5.5V

MAX-M10M-00B-01 Overview

Part: MAX-M10M-00B-01 — u-blox Type: Standard precision GNSS module Description: Ultra-low-power GNSS receiver for high-performance asset-tracking applications, supporting concurrent reception of four GNSS constellations (GPS, GLONASS, Galileo, BeiDou) with less than 10 mW power consumption in cyclic tracking power save mode.

Operating Conditions:

  • Supply voltage: 1.76–5.5 V (VCC), 1.68–1.98 V (V_IO with VIO_SEL=GND)
  • Operating temperature: -40 to +85 °C
  • Max navigation update rate: 20 Hz (GPS+GAL, high performance)
  • Position accuracy (CEP): 1.5 m (GPS+GAL)

Absolute Maximum Ratings:

  • Max supply voltage (VCC): 6 V
  • Max IO supply voltage (V_IO): 3.6 V
  • Max source / sink current, digital pins: 10 mA
  • Max RF input power on RF_IN: +15 dBm
  • Max ambient temperature: +85 °C
  • Max storage temperature: +85 °C

Key Specs:

  • Receiver type: u-blox M10 receiver
  • Power consumption: < 10 mW (1 Hz cyclic tracking power save mode)
  • Velocity accuracy: 0.05 m/s
  • Dynamic heading accuracy: 0.3 deg
  • Time To First Fix (TTFF) Cold start: 23 s (GPS+GAL+GLO)
  • Time To First Fix (TTFF) Hot start: 1 s
  • Sensitivity (Tracking and nav.): -167 dBm (GPS+GAL+GLO)
  • Supported GNSS: GPS, GLONASS, Galileo, BeiDou (concurrent reception of four)

Features:

  • Ultra-low-power consumption
  • Concurrent reception of four GNSS constellations
  • u-blox Super-S (Super-Signal) technology for improved RF sensitivity
  • Backwards pin-to-pin compatibility with previous u-blox generations
  • Antenna supervisor for active antenna control and short detection
  • CloudLocate GNSS for energy-constrained IoT applications
  • Assisted GNSS (AssistNow Online, Offline, Autonomous)
  • Power save modes (On/off, cyclic tracking)
  • Anti-jamming and anti-spoofing
  • Secure boot and message integrity

Applications:

  • High-performance asset-tracking applications

Package:

  • 18-pin module

MAX-M10M-00B-01 Features

FeatureDescription
Antenna supervisor 14Antenna supervisor for active antenna control and short detection
CloudLocateGNSSExtends the life of energy-constrained IoT applications. Small payload messages supported.
AssistedGNSSAssistNow Online, AssistNow Offline and AssistNow Autonomous
Backup modesHardware backup mode and software standby mode
Power save modes 15On/off, cyclic tracking
Super-SImproved dynamic position accuracy with small antennas
Protection levelReal-time position accuracy estimate with 95%confidence level 16
Galileo return link messagesGalileo search and rescue (SAR) return link messages (RLM) via Galileo satellite signal
FeatureDescription
Data batchingAutonomous tracking up to 10 minutes at 1 Hz
OdometerMeasure traveled distance with support for different user profiles
Table 8: Firmware featuresTable 8: Firmware features
FeatureDescription
Anti-jammingRF interference and jamming detection and reporting
Anti-spoofingSpoofing detection and reporting
Configuration lockdownReceiver configuration can be lockedbycommand
Message integrityAll messages can be cryptographically signed
Secure bootOnly signed firmware images executed

Table 9: Security features

MAX-M10M-00B-01 Pin Configuration

Figure 2: MAX-M10M pin assignment

Figure 2: MAX-M10M pin assignment

Pin no.NamePIO no.I/ODescription
1GND--ConnecttoGND
2TXD1OUARTTX
3RXD0IUARTRX
4TIMEPULSE4OTime pulse signal (shared with SAFEBOOT_N pin) 17
5EXTINT5IExternal interrupt
6V_BCKP-IBackup voltage supply
7V_IO-IIO voltage supply
8VCC-IMain voltage supply
9RESET_N-ISystem reset (active low). Has to be low for at least 1 msto trigger a reset.
10GND--ConnecttoGND
11RF_IN-IGNSSsignal input
12GND--ConnecttoGND
13LNA_EN-OOn/Off external LNAor active antenna
14VCC_RF-OOutput voltage RF section
15VIO_SEL-IVoltage selector for V_IO supply. Connect to GNDfor 1.8 Vsupply, or leave open for 3.3 Vsupply.
16SDA2I/OI2C data
17SCL3II2C clock
18SAFEBOOT_N-ISafeboot mode (leave open) 17

MAX-M10M-00B-01 Electrical Characteristics

CAUTION Operating the device above one or more of the limiting values may cause permanent damage to the device. The values provided in this chapter are stress ratings. Extended exposure to the values outside the limits may effect the device reliability.

  • Where application information is given, it is advisory only and does not form part of the specification.

MAX-M10M-00B-01 Absolute Maximum Ratings

SymbolParameterMinMaxUnit
VCCMain supply voltage-0.36V
V_IOIO supply voltage-0.33.6V
Voltage ramp on V_IO 182535000μs/V
V_BCKPBackup supply voltage-0.33.6V
V_PIOInput voltage on RESET_N and digital pins. VIO_SEL = GND.-0.3V_IO + 0.3 (max 1.98)V
Input voltage on RESET_N and digital pins. VIO_SEL = open.-0.3V_IO + 0.3 (max 3.6)V
I_PIOMax source / sink current, digital pins 19-1010mA
ICC_RFMax source current, VCC_RF250mA
P rfinRF input power on RF_IN 20+15dBm
T ambAmbient temperature-40+85°C
T sStorage temperature-40+85°C

Table 12: Absolute maximum ratings

The product is not protected against overvoltage or reversed voltages. Voltage spikes exceeding the power supply voltage specification, given in the table above, must be limited to values within the specified boundaries by using appropriate protection diodes.

Variants on the same datasheet

These parts have exact links to the same datasheet. They are candidates to compare, not verified drop-in replacements; check package, pinout and electrical limits.

Part NumberManufacturerPackage
MAX-M10Mu-bloxLCC-18
MAX-M10M-00Bu-blox18-SMD Module

More datasheets

All u-blox datasheets (19)

Data on this page is extracted from publicly available manufacturer datasheets using automated tools including AI. It may contain errors or omissions. Always verify specifications against the official manufacturer datasheet before making design or purchasing decisions. See our Terms of Service. Rights holders can submit a takedown request.

Ask your AI agent about the MAX-M10M-00B-01

Connect SheetsData to Claude, Cursor, Codex or any MCP client and your agent reads this datasheet for you: pinout, limits, register maps and design checks, with the numbers taken from the PDF.

claude mcp add --transport http sheetsdata https://mcp.sheetsdata.com/mcp

Then ask: "Can the MAX-M10M-00B-01 run from my 12 V rail? Check it against the datasheet limits."

Create a free account $2 of usage every month, no card needed.