LTC3337ACBZ-R7
Primary Battery SOH MonitorThe LTC3337ACBZ-R7 is a primary battery soh monitor from Analog Devices. View the full LTC3337ACBZ-R7 datasheet below including key specifications, electrical characteristics, absolute maximum ratings.
LTC3337ACBZ-R7 shares its datasheet with LTC3337, whose page lists every part number it covers.
Official LTC3337ACBZ-R7 datasheet (PDF) — the source this page was extracted from.
LTC3337ACBZ-R7 Key Specifications
| Parameter | Value |
|---|---|
| Quiescent Current | 100nA typ (160nA max) |
| AVCC Voltage Range | 1.8V to 5.5V |
| Package Dimensions | 1.64mm × 1.64mm × 0.47mm |
| Voltage Monitor LSB | 1.465mV |
| Communication Interface | I2C (7-bit address 1100100) |
| Temperature Monitor LSB | 0.784°C |
| Battery Input Voltage Range | 1.8V to 5.5V |
| Total Coulomb Counter Error | ±3% |
| Total Voltage Monitor Error | ±1.0% (±2.5% over temperature) |
| Supercapacitor Balancer Current | ±10mA |
| Peak Input Current Limit Settings | 5mA/10mA/15mA/20mA/25mA/50mA/75mA/100mA |
| Supercapacitor Balancer Input Range | 2.5V to 5.5V |
| Operating Junction Temperature Range | -40°C to 125°C |
LTC3337ACBZ-R7 Overview
Part: LTC3337 — Analog Devices (Linear Technology)
Type: Primary Battery State-of-Health Monitor with Coulomb Counter
Description: 1.8–5.5 V primary battery SOH monitor with a precision coulomb counter, 100 nA quiescent current, pin-selectable 5–100 mA peak input current limit, and an I²C interface.
Operating Conditions:
- Supply voltage (BAT_IN, AVCC, DVCC): 1.8–5.5 V
- Operating junction temperature: -40 to 125 °C
- Peak input current limit: 5/10/15/20/25/50/75/100 mA, pin selectable
- Coulomb counter and peak current limit accuracy are best for BAT_IN above 2 V
- I²C clock: up to 400 kHz
Absolute Maximum Ratings:
- BAT_IN, BAT_OUT, AVCC voltage: -0.3 to 6 V
- DVCC, SCL, SDA voltage: -0.3 to 6 V
- BAT_OUT current: 150 mA
- IRQ, BATOUT_OK current: ±1 mA
- SDA current: 5 mA
- Operating junction temperature: -40 to 125 °C
- Storage temperature: -65 to 150 °C
- Maximum reflow (package body) temperature: 260 °C
Key Specs:
- AVCC quiescent current (BAT_IN - BAT_OUT = 50 mV): 100 nA typ, 160 nA max
- Peak input current (100 mA setting, BAT_IN - BAT_OUT = 175 mV): 100 mA typ, 90–110 mA at 25 °C
- Total coulomb counter error: ±3 % (production tested at the 100 mA setting)
- Voltage monitor: 1.465 mV LSB, total error ±1.0 % (±2.5 % over the full junction temperature range), full scale 6 V
- Temperature monitor: 0.784 °C LSB, range -41 to 159 °C
- Supercapacitor balancer: ±10 mA source/sink, balance point 50 % of BAT_OUT (49–51 %), input range 2.5–5.5 V, 62 nA typ quiescent current
- Full-scale coulomb count: 977.3 A·hr typ (100 mA setting, M=0); 1.491 mA·hr (5 mA setting, M=15)
- BATOUT_OK threshold (BAT_IN - BAT_OUT): 110 mV typ rising, 400 mV typ falling
Features:
- SOH monitor for primary batteries
- Integrated coulomb counter that counts either BAT_IN or BAT_OUT current, selected by the AVCC pin connection
- Additional monitors for battery voltage, battery impedance, and temperature
- Programmable coulomb counter prescaler for a wide range of battery sizes
- Programmable discharge alarm threshold with IRQ interrupt output
- Integrated ±10 mA supercapacitor balancer
- I²C interface
Applications:
- Low power primary battery powered systems (e.g., 1× LiSOCl₂, 2–3× alkaline)
- Remote industrial sensors (meters, alarms)
- Asset trackers
- Electronic door locks
- Keep-alive supplies and battery backup
- SmartMesh applications
Package:
- 12-Lead LFCSP, 2 mm × 2 mm × 0.75 mm (LTC3337ERC)
- 16-Ball WLCSP, 1.64 mm × 1.64 mm × 0.47 mm (LTC3337ACBZ)
LTC3337ACBZ-R7 Applications
- n Low Power Primary Battery Powered Systems (e.g., 1× LiSOCl 2 , 2-3× Alkaline)
- n Remote Industrial Sensors (e.g., Meters, Alarms)
- n Asset T rackers
- n Electronic Door Locks
- n Keep-Alive Supplies/Battery Backup
- n SmartMesh ® Applications
LTC3337ACBZ-R7 Pin Configuration
LFCSP PACKAGE 12-LEAD (2mm × 2mm × 0.75mm) PLASTIC QFN T JMAX = 125°C, θ JA = 52.78°C/W EXPOSED PAD (PIN 13) IS GND, MUST BE SOLDERED TO PCB
LTC3337ACBZ-R7 Electrical Characteristics
The l denotes the specifications which apply over the full operating junction temperature range, otherwise specifications are at T A = 25°C. (Note 2). BAT_IN = BAT_OUT = AV CC = DV CC = 3.6V unless otherwise noted.
| PARAMETER | CONDITIONS | MIN TYP | MAX | UNITS |
|---|---|---|---|---|
| Bus Free Time Between STOP/START | t BUF | 1.3 | μs | |
| Repeated START Set-Up Time | t SU,STA | 600 | ns | |
| Hold Time (Repeated) START Condition | t HD,STA | 600 | ns | |
| Set-Up Time for STOP Condition | t SU,STO | 600 | ns | |
| Data Set-Up Time (Input) | t SU,DAT | 100 | ns | |
| Data Hold Time (Input) | t HD,DATI | 0 | μs | |
| Data Hold Time (Output) | t HD,DATO | 0 | 0.9 | μs |
| Clock/Data Fall Time | t f | 20 | 300 | ns |
| Clock/Data Rise Time | t r | 20 | 300 | ns |
| Clock LOW Period | t LOW | 1.3 | μs | |
| Clock HIGH Period | t HIGH | 0.6 | μs | |
| Spike Suppression Time | t SP | 50 | ns |
Note 1: Stresses beyond those listed under Absolute Maximum Ratings may cause permanent damage to the device. Exposure to any Absolute Maximum Rating condition for extended periods may affect device reliability and lifetime.
Note 2: The LTC3337 is specified over the -40°C to 125°C operating junction temperature range. High junction temperatures degrade operating lifetimes. Note the maximum ambient temperature consistent with these specifications is determined by specific operating conditions in conjunction with board layout, the rated package thermal impedance and other environmental factors.
Note 3: T J is calculated from the ambient T A and power dissipation P D according to the following formula: T J = T A + (P D · θ JA ).
Note 4: Coulomb counter and peak current limit accuracy are at their best for BAT_IN voltages above 2V. Voltage and Temperature Monitor accuracy are at their best down to 1.8V. See Extended Battery Range Below 2V in the Operation section.
LTC3337ACBZ-R7 Absolute Maximum Ratings
BAT_IN, BAT_OUT, AV CC Voltage .................. -0.3V to 6V (BAT_OUT - BAT_IN) Differential Voltage ................0.3V DVCC , SCL, SDA Voltage .............................. -0.3V to 6V IPK[2:0] Voltage ................................-0.3V to [Lesser of (BAT_IN + 0.3V) or 6V] BAL Voltage ......................................-0.3V to [Lesser of (BAT_OUT + 0.3V) or 6V]
LTC3337ACBZ-R7 Typical Application
The LTC ® 3337 is a primary battery state of health (SOH) monitor with a built-in precision coulomb counter . It is designed to be placed in series with a primary battery with minimal associated series voltage drop. The patented infinite dynamic range coulomb counter tallies ALL accumulated battery discharge and stores it in an internal register accessible via an I 2 C interface. A discharge alarm threshold based on this state of charge (SOC) is programmable. When it is reached, an interrupt is generated at the IRQ pin. Coulomb counter accuracy is constant down to no load.
The LTC3337 also integrates additional SOH monitoring which measures and reports via I 2 C: battery voltage, battery impedance, and temperature.
To accommodate a wide range of primary battery inputs, the peak input current limit is pin selectable from 5mA to 100mA.
Coulombs can be calculated for either the BAT_IN or BAT_OUT pin, determined by the AV CC pin connection.
A BAL pin is provided for applications utilizing a stack of two supercapacitors (optional) at the output.
The LTC3337 is offered in both 12-lead 2mm × 2mm LFCSP and 16-ball 1.64mm × 1.64mm WLCSP packages.
All registered trademarks and trademarks are the property of their respective owners. Protected by U.S. patents, including 9312815.
Variants on the same datasheet
These parts have exact links to the same datasheet. They are candidates to compare, not verified drop-in replacements; check package, pinout and electrical limits.
| Part Number | Manufacturer | Package |
|---|---|---|
| LTC3337 | Analog Devices | — |
| LTC3337ERC | Analog Devices | LFCSP-12 2x2mm |
| LTC3337S | Analog Devices | — |
More datasheets
Ask your AI agent about the LTC3337ACBZ-R7
Connect SheetsData to Claude, Cursor, Codex or any MCP client and your agent reads this datasheet for you: pinout, limits, register maps and design checks, with the numbers taken from the PDF.
claude mcp add --transport http sheetsdata https://mcp.sheetsdata.com/mcp
Then ask: "Can the LTC3337ACBZ-R7 run from my 12 V rail? Check it against the datasheet limits."
Create a free account $2 of usage every month, no card needed.