HLK-PM03 Key Specifications
| Parameter | Value |
|---|---|
| Input Voltage Range | 85V to 265V AC / 70V to 350V DC |
| Rated input voltage | 100-240 Vac |
| Maximum input current | ≤0.1 A |
| No-load rated output voltage (HLK-PM03) | 3.3±0.1 Vdc |
| Full-load rated output voltage (HLK-PM03) | 3.3±0.2 Vdc |
| Rated output current (HLK-PM03) | 1000 mA |
| Input low voltage efficiency (Vin=115Vac, full load) | ≥72 % |
| Output ripple and noise (HLK-PM03) | ≤100 mVp-p (Rated input voltage, output full load, 20MHz bandwidth) |
| Input and output isolation voltage | 3000 Vac |
HLK-PM03 Overview
Part: HLK-PM03 — Shenzhen Hi-Link Electronic Co., Ltd.
Type: AC DC Power Module
Description: A 3W ultra-small AC DC power module with a global universal input voltage range of 85-265Vac (or 70-350Vdc), offering high efficiency, low ripple, and high safety isolation.
Operating Conditions:
- Supply voltage: 85-265 Vac or 70-350 Vdc
- Operating temperature: -25 to +60 °C
- Relative humidity: 5-95 %
- Altitude: ≤2000 m
Key Specs:
- Rated input voltage: 100-240 Vac
- Maximum input current: ≤0.1 A
- No-load rated output voltage (HLK-PM03): 3.3±0.1 Vdc
- Full-load rated output voltage (HLK-PM03): 3.3±0.2 Vdc
- Rated output current (HLK-PM03): 1000 mA
- Input low voltage efficiency (Vin=115Vac, full load): ≥72 %
- Output ripple and noise (HLK-PM03): ≤100 mVp-p (Rated input voltage, output full load, 20MHz bandwidth)
- Input and output isolation voltage: 3000 Vac
Features:
- Ultra-thin, ultra-small volume
- Global universal input voltage (90~265Vac)
- Low power consumption, no-load loss<0.1W
- Low ripple, low noise
- High output short circuit and over-current protection and self recovery
- High efficiency, high power density
- 100% full load aging and testing
- High reliability, long life design (>100,000 hours)
- Meets UL, CE requirements; product design meets EMC and safety testing requirements
- High-quality environmentally friendly waterproof plastic potting, meets IP65 standards
- Works without external circuit
- 1 year quality guarantee period
Applications:
- Smart home
- Automation control
- Communications equipment
- Instrumentation
Package:
- Module dimensions: 34 x 20 x 15 mm
- Weight: 20±2g
- Pin functions: AC, AC, -V0, +V0
HLK-PM03 Features
- Ultra-thin, ultra-small, smallest volume;
- Global universal input voltage (90~265Vac)
- Low power consumption, green environmental protection, no-load loss<0.1W
- Low ripple, low noise
- High output short circuit and over-current protection and self recovery
- High efficiency, high power density
- Input and output isolation voltage 3000Vac
- 100% full load aging and testing
- High reliability, long life design, continuous working time is greater than 100,000 hours;
- Meet UL, CE requirements; product design to meet EMC and safety testing requirement;
- Using high-quality environmentally friendly waterproof plastic potting, moisture, vibration, water and dust to meet IP65 standards
- Economic solutions, cost-effective
- Work without external circuit
- 1 year quality guarantee period
HLK-PM03 Typical Application
9
/
HLK-PM03 Ordering Information
| MPN | Package | Temperature Range | Packing |
|---|---|---|---|
| HLK-PM03 | 342015 mm | -25 to +60 °C | Special plastic boxes separated |
| HLK-PM01 | 342015 mm | -25 to +60 °C | Special plastic boxes separated |
| HLK-PM09 | 342015 mm | -25 to +60 °C | Special plastic boxes separated |
| HLK-PM12 | 342015 mm | -25 to +60 °C | Special plastic boxes separated |
| HLK-PM15 | 342015 mm | -25 to +60 °C | Special plastic boxes separated |
| HLK-PM24 | 342015 mm | -25 to +60 °C | Special plastic boxes separated |
Variants on the same datasheet
These parts have exact links to the same datasheet. They are candidates to compare, not verified drop-in replacements; check package, pinout and electrical limits.
More datasheets
Ask your AI agent about the HLK-PM03
Connect SheetsData to Claude, Cursor, Codex or any MCP client and your agent reads this datasheet for you: pinout, limits, register maps and design checks, with the numbers taken from the PDF.
claude mcp add --transport http sheetsdata https://mcp.sheetsdata.com/mcp
Then ask: "Can the HLK-PM03 run from my 12 V rail? Check it against the datasheet limits."
Create a free account $2 of usage every month, no card needed.