ETX900
TSO BatteryThe ETX900 is a tso battery from EarthX, Inc.. View the full ETX900 datasheet below including key specifications.
ETX900 shares its datasheet with ETX900-24, whose page lists every part number it covers.
Official ETX900 datasheet (PDF) — the source this page was extracted from.
Manufacturer
EarthX, Inc.Category
TSO Battery
ETX900 Key Specifications
| Parameter | Value |
|---|---|
| Certification | TSO-C179b, DO-311A, DO-160G |
| Cell Chemistry | Lithium Iron Phosphate (LiFePO4), 4 cells in series |
| BMS Part Number | BMS_DR (DAL C) |
| Cranking Duty Limit | 10-30 seconds in any 60 second period |
| Capacity Equivalence | 16Ah lithium equals 22Ah lead-acid usable capacity |
| Nominal Cell Voltage | 3.3V |
| Fault Discrete Output | Current sinking, 100mA max, 1/4 inch quick connect terminal |
| Cooldown Reconnect Time | 1-3 minutes |
| Fault Indication States | Fast flashing (2 s on/2 s off), slow flashing (5 s on/5 s off), solid |
| Nominal Battery Voltage | 13.2V (full charge >13.3V) |
| Short Circuit Protection | >1000A |
| Over-Discharge Disconnect | Below 5% remaining charge (typically <11.5V) |
| Charge Current Blocked Above | 16V (resistance increases above 15.5V, 2 s delay) |
| Battery Terminal Screw Torque | 45 in-lbs |
| Maximum Charge Current Rating | 80A |
| Maximum Aircraft Charging System Voltage | 16V |
ETX900 Overview
Part: ETX900-TSO-REVx — EarthX, Inc.
Type: Lithium Iron Phosphate (LiFePO4) Starting Battery
Description: 13.2 V, 15.6 Ah LiFePO4 starting battery with integrated Battery Management System (BMS) and thermal runaway containment, designed as a maintenance-free replacement for 12-volt lead-acid or lithium starter batteries in 14 CFR part 23 Aircraft.
Operating Conditions:
- Supply voltage: 13.9–14.6 V (Standard Charge Voltage)
- Operating temperature: -30 °C to +60 °C (short term +65 °C)
- Max altitude: 25,000 Ft
- Max charge current: 80 A (from aircraft charging system)
Absolute Maximum Ratings:
- Max charge voltage: 16 V (from aircraft charging system)
- Max continuous discharge current: 31 A
- Max short term environmental temperature (on ground): 85 °C (30 minutes)
- Max storage temperature: +70 °C
Key Specs:
- Nominal Voltage: 13.2 V
- Capacity (1C, 1hour rate at 23 °C): 15.6 Ah
- Peak Power (Ipp, 23/-18 °C): 800 / 390 amps
- Rated Power (Ipr, 23/-18 °C): 600 / 365 amps
- Self-Discharge Rate: <3%/month @25°C
- Life (Charge cycles): 4000 cycles @1C discharge rate, 25 °C (20% depth of discharge)
- Weight: 5.4 lb
- Dimensions: 166mm (L) x 79mm (W) x 168mm (H)
Features:
- Integrated Battery Management System (BMS) with cell balancing and over-charge protection.
- Over-discharge protection (disconnects below 5% charge, <11.5V).
- Excessive cranking protection (limits high current use to 10-30 seconds in any 60-second period).
- High temperature protection.
- Short-circuit protection (>1000 Amps).
- Redundant main electronic battery disconnect components.
- Thermal runaway containment system with vent tubes.
- Charge voltage protection greater than 60V (blocks charging current above 16V).
- Built-in LED indicator and discrete output for fault monitoring (fast flashing for high temp, slow flashing for improper state of charge/cell problem, solid for BMS hardware failure).
- IP 66 environmental rating (resistance to water intrusion).
Applications:
- 14 CFR part 23 Aircraft (as a maintenance-free replacement for 12-volt lead-acid or lithium starter batteries).
Package:
- 6.5in (L) x 3.1in (W) x 6.6in (H) (166mm x 79mm x 168mm)
Variants on the same datasheet
These parts have exact links to the same datasheet. They are candidates to compare, not verified drop-in replacements; check package, pinout and electrical limits.
| Part Number | Manufacturer | Package |
|---|---|---|
| ETX900-24 | EarthX, Inc. | — |
| ETX900-TSO | EarthX, Inc. | — |
| ETX900-TSO-REVX | EarthX, Inc. | — |
More datasheets
Ask your AI agent about the ETX900
Connect SheetsData to Claude, Cursor, Codex or any MCP client and your agent reads this datasheet for you: pinout, limits, register maps and design checks, with the numbers taken from the PDF.
claude mcp add --transport http sheetsdata https://mcp.sheetsdata.com/mcp
Then ask: "Can the ETX900 run from my 12 V rail? Check it against the datasheet limits."
Create a free account $2 of usage every month, no card needed.