EC200U-EU
LTE Standard ModuleThe EC200U-EU is a lte standard module from Quectel. View the full EC200U-EU datasheet below including absolute maximum ratings.
EC200U-EU shares its datasheet with EC200UEUAA-N05-SGNSA, whose page lists every part number it covers.
Official EC200U-EU datasheet (PDF) — the source this page was extracted from.
Manufacturer
QuectelCategory
LTE Standard Module
EC200U-EU Overview
Part: EC200U Series, Quectel Wireless Solutions Co., Ltd.
Type: LTE Standard Module Series
Description: A hardware design document for the EC200U Series LTE Standard Module.
Operating Conditions:
Absolute Maximum Ratings:
Key Specs:
- No key specifications are provided in the document extract.
Features:
- No specific features are detailed in the document extract.
Applications:
- No specific applications are detailed in the document extract.
Package:
EC200U-EU Features
Table 4: Key Features of EC200U Series Module
| Feature | Details |
|---|---|
| Power Supply | ⚫ Supply voltage: 3.3 - 4.3 V ⚫ Typical supply voltage: 3.8 V |
| Transmitting Power | ⚫ Class 4 for EGSM850 ⚫ Class 4 for EGSM900 ⚫ Class 1 for DCS1800 ⚫ Class 1 for PCS1900 ⚫ Class 3 for LTE-FDD bands |
| LTE Features | ⚫ Supports Cat 1 FDD and TDD ⚫ Supports 1.4/3/5/10/15/20 MHz RF bandwidth ⚫ FDD: Max. 10 Mbps (DL), Max. 5 Mbps (UL) ⚫ TDD: Max. 8.96 Mbps (DL), Max. 3.1 Mbps (UL) |
| GSM Features | GPRS: ⚫ Supports GPRS multi-slot class 12 ⚫ Coding scheme: CS-1, CS-2, CS-3 and CS-4 ⚫ Max. 85.6 kbps (DL)/Max. 85.6 kbps (UL) |
| Internet Protocol Features | ⚫ Supports TCP/UDP/PPP/NTP/NITZ/FTP/HTTP/PING/CMUX/HTTPS/ FTPS/SSL/FILE/MQTT/MMS protocols ⚫ Supports PAP and CHAP for PPP connections |
| SMS | ⚫ Text and PDU mode ⚫ Point to point MO and MT ⚫ SMS cell broadcast ⚫ SMS storage: Stored in (U) SIM card and ME, stored in ME by default |
Table 4: Key Features of EC200U Series Module
| (U)SIM Interface | ⚫ Supports USIM/SIM card: 1.8/3.0 V ⚫ Supports DSDS |
|---|---|
| Audio Features | ⚫ Supports one analog audio input and one analog audio output ⚫ GSM: HR/FR/EFR/AMR/AMR-WB ⚫ Supports echo cancellation and noise suppression |
| USB Interface | ⚫ Compliant with USB 2.0 specification (slave mode only); the data transfer rate can reach up to 480 Mbps ⚫ Used for AT command communication, data transmission, software debugging, firmware upgrade ⚫ Supports USB serial drivers for Windows 7/8/8.1/10, Linux 2.6 - 5.12, Android 4.x - 11.x, etc. |
| UART Interfaces | Main UART: ⚫ Used for AT command communication and data transmission ⚫ Baud rates reach up to 921600 bps; 115200 bps by default ⚫ Support MAIN_RTS and MAIN_CTS hardware flow control Debug UART: ⚫ Used for Linux console and log output ⚫ 921600 bps baud rates ⚫ Can only be used as a debugging UART, not a general UART Auxiliary UART |
| I2C Interfaces | ⚫ Two I2C interfaces |
| SPI Interface | ⚫ SPI interface only supports master mode |
| SD Card Interface | ⚫ SD 2.0 protocol compliant |
| WLAN Application Interface* | ⚫ Supports SDIO 1.1 interface for WLAN function |
| LCD Interface | ⚫ LCD interface supporting SPI mode |
| Matrix keyboard Interfaces | ⚫ Support 4 ×4 matrix keyboard |
| ADC Interfaces | ⚫ ThreeADC interfaces |
| USB_BOOT Interface | ⚫ Forced download interface |
| AT Commands | ⚫ Compliant with 3GPP TS 27.007, 3GPP TS 27.005 and Quectel enhanced AT commands |
| Network Indication | ⚫ NET_MODE and NET_STATUS to indicate network connectivity status |
| Antenna Interfaces | ⚫ Main antenna interface (ANT_MAIN), Wi-Fi Scan/Bluetooth antenna interface (ANT_BT/WIFI_SCAN) and GNSS 4 antenna interface (ANT_GNSS) |
| ⚫ 50 Ω impedance | |
| Location | ⚫ Supports Wi-Fi Scan/GNSS 4 |
| Physical Characteristics | ⚫ Size: (28.0 ±0.15)mm ×(31.0 ±0.15)mm ×(2.4 ±0.2)mm ⚫ Weight: approx. 4.1 g |
| Temperature Ranges | ⚫ Operating temperature range: -35 ° C to +75 ° C 5 ⚫ Extended temperature range: -40 ° C to +85 ° C 6 ⚫ Storage temperature range: -40 ° C to +90 ° C |
| Firmware Upgrade | ⚫ USB interface or FOTA |
| RoHS | ⚫ All hardware components are fully compliant with EU RoHS directive |
EC200U-EU Pin Configuration
The following figure shows the pin assignment of EC200U series module.
Figure 2: Pin Assignment (Top View)
- USB_BOOT and KEYIN1 cannot be pulled up before the module's successful startup.
- Please keep all RESERVED and unused pins unconnected, and all GND pins are connected to the ground.
- Pin 85-112 should be connected to the ground.
EC200U-EU Absolute Maximum Ratings
Absolute maximum ratings for power supply and voltage on digital and analog pins of the module are listed in the following table.
Table 38: Absolute Maximum Ratings
| Parameter | Min. | Max. | Unit |
|---|---|---|---|
| VBAT_RF/VBAT_BB | -0.3 | 6.0 | V |
| USB_VBUS | -0.3 | 5.5 | V |
| Peak Current of VBAT_BB | - | 1.5 | A |
| Peak Current of VBAT_RF | - | 2.0 | A |
| Voltage at Digital Pins | -0.3 | 2.3 | V |
| Voltage atADC0 | 0 | VBAT_BB | V |
| Voltage atADC1 | 0 | VBAT_BB | V |
| Voltage atADC2 | 0 | VBAT_BB | V |
Table 38: Absolute Maximum Ratings
More datasheets
Ask your AI agent about the EC200U-EU
Connect SheetsData to Claude, Cursor, Codex or any MCP client and your agent reads this datasheet for you: pinout, limits, register maps and design checks, with the numbers taken from the PDF.
claude mcp add --transport http sheetsdata https://mcp.sheetsdata.com/mcp
Then ask: "Can the EC200U-EU run from my 12 V rail? Check it against the datasheet limits."
Create a free account $2 of usage every month, no card needed.