D08-A90SMD Key Specifications

ParameterValue
Fail ShortNo
Impulse Discharge Current (8/20µs)10000A (10kA)
Mounting TypeSurface Mount
Number of Poles2
Package / Case2-SMD
PackagingMouseReel
Standard Pack Qty1700
Tolerance±20%
Voltage - DC Spark Over (Nom)90 V

D08-A90SMD Overview

Part: D08-A90SMD B88069X4653T173 (TDK Electronics AG)

Type: 2-electrode arrester

Description: A 2-electrode surge arrester with a flat design, high current rating, and stable performance, featuring a nominal DC spark-over voltage of 90 V and impulse spark-over voltage less than 350 V at 100 V/μs.

Operating Conditions:

  • Supply voltage: Not applicable (passive component)
  • Operating temperature: -40 to +125 °C
  • Climatic category: 40/125/21

Absolute Maximum Ratings:

  • Max supply voltage: 108 V (Max DC spark-over voltage)
  • Max continuous current: Not applicable (impulse current rated)
  • Max junction/storage temperature: 125 °C

Key Specs:

  • DC spark-over voltage: 90 V ±20% (Min 72 V, Max 108 V)
  • Impulse spark-over voltage at 100 V/μs: < 350 V (for 99% of measured values)
  • Impulse spark-over voltage at 1 kV/μs: < 550 V (for 99% of measured values)
  • Service life (10 operations, 8/20 μs): 10 kA
  • Service life (1 operation, 10/350 μs): 15 kA
  • Insulation resistance at 50 V DC: > 1 GΩ
  • Capacitance at 1 MHz: < 2 pF
  • Weight: ~ 0.5 g

Features:

  • Flat design
  • High current rating
  • Stable performance over life
  • High insulation resistance
  • Excellent SMD handling
  • RoHS-compatible

Applications:

  • Telecom
  • Industrial communication
  • Line protection
  • Subscriber protection
  • Alarm system

Package:

  • SMD

D08-A90SMD Features

  • Flat design
  • High current rating
  • Stable performance over life
  • High insulation resistance
  • Excellent SMD handling
  • RoHS-compatible

D08-A90SMD Applications

  • Telecom
  • Industrial communication
  • Line protection
  • Subscriber protection
  • Alarm system

D08-A90SMD Electrical Characteristics

DC spark-over voltage 1) 2) Tolerance Min. Max.DC spark-over voltage 1) 2) Tolerance Min. Max.90 ±20 72 108V % V V
Impulse spark-over voltageImpulse spark-over voltage
at 100 V/μs at 1 kV/μs- for 99% of measured values - typical values of distribution - for 99% of measured values - typical values of distribution< 350 < 300 < 550 < 500V V V V
Service lifeService life
10 operations 10 operations 1 operation 2 operations 300 operations50 Hz, 1 s 8/20 μs 8/20 μs 10/350 μs 10/1000 μs5 10 15 2.5 100A kA kA kA A
Insulation resistance at 50 VDC> 1G
Capacitance at 1 MHz Arc voltage at 1 A Glow to arc transition current Glow voltageCapacitance at 1 MHz Arc voltage at 1 A Glow to arc transition current Glow voltage< 2pF
WeightWeight~ 0.5g
Operation and storage temperatureOperation and storage temperature
40 ...°C
Climatic category (IEC 60068-1)Climatic category (IEC 60068-1)40/125/2140/125/21
MarkingMarkingwithoutwithout

Terms in accordance with ITU-T Rec. K.12 and IEC 61643-311

Variants on the same datasheet

These parts have exact links to the same datasheet. They are candidates to compare, not verified drop-in replacements; check package, pinout and electrical limits.

Part NumberManufacturerPackage
B88069X4653TDKD08-A90SMD
B88069X4653T173TDK2-SMD

More datasheets

All TDK datasheets (29)

Data on this page is extracted from publicly available manufacturer datasheets using automated tools including AI. It may contain errors or omissions. Always verify specifications against the official manufacturer datasheet before making design or purchasing decisions. See our Terms of Service. Rights holders can submit a takedown request.

Ask your AI agent about the D08-A90SMD

Connect SheetsData to Claude, Cursor, Codex or any MCP client and your agent reads this datasheet for you: pinout, limits, register maps and design checks, with the numbers taken from the PDF.

claude mcp add --transport http sheetsdata https://mcp.sheetsdata.com/mcp

Then ask: "Can the D08-A90SMD run from my 12 V rail? Check it against the datasheet limits."

Create a free account $2 of usage every month, no card needed.