BQ35100PWR
Battery Fuel GaugeThe BQ35100PWR is a battery fuel gauge from Texas Instruments. View the full BQ35100PWR datasheet below including key specifications, absolute maximum ratings.
BQ35100PWR shares its datasheet with BQ35100, whose page lists every part number it covers.
Official BQ35100PWR datasheet (PDF) — the source this page was extracted from.
Manufacturer
Texas InstrumentsCategory
Battery Fuel Gauge
Lifecycle
Production (Last Updated: 2 days ago)
BQ35100PWR Key Specifications
| Parameter | Value |
|---|---|
| Ambient Temperature Range High | 85 °C |
| Case/Package | TSSOP |
| Height | 0 m |
| Lead Free | Lead Free |
| Length | 5 mm |
| Lifecycle Status | Production (Last Updated: 2 days ago) |
| Manufacturer Lifecycle Status | ACTIVE (Last Updated: 2 days ago) |
| Max Operating Temperature | 85 °C |
| Max Supply Voltage | 4.5 V |
| Min Operating Temperature | -40 °C |
| Min Supply Voltage | 2.45 V |
| Number of Cells | 1 |
| Number of Outputs | 1 |
| Number of Pins | 14 |
| Output Current | 250 mA |
| Output Voltage | 2.5 V |
| RoHS | Compliant |
| Schedule B | 8542390000, 8542390000|8542390000, 8542390000|8542390000|8542390000, 8542390000|8542390000|8542390000|8542390000 |
| Thickness | 1 mm |
| Width | 4.4 mm |
BQ35100PWR Overview
Part: BQ35100 (BQ35100PW) — Texas Instruments
Type: Lithium Primary Battery Fuel Gauge and End-of-Service Monitor
Description: Fuel gauge and end-of-service monitor for Li-SOCl2 and Li-MnO2 primary batteries with a 2.7–4.5 V supply, I²C interface and average current as low as ~0.06 μA (SOH mode, update every 8 hours).
Operating Conditions:
- Supply voltage (VREGIN): 2.7–4.5 V with no operating restrictions; 2.45–2.7 V with no flash writes
- Operating temperature: -40 to 85 °C
- I²C communication at up to 400 kHz
- LDO output capacitor (CLDO25): 0.47 μF min, 1 μF nominal
Absolute Maximum Ratings:
- VREGIN regulator input: -0.3 to 5.5 V
- VREG25 supply: -0.3 to 2.75 V
- Open-drain I/O (SDA, SCL, VEN): -0.3 to 5.5 V; ALERT: -0.3 to 2.75 V
- BAT input: -0.3 to 5.5 V
- SRN, SRP, TS inputs: -0.3 to VREG25 + 0.3 V
- Storage temperature: -65 to 150 °C
- ESD HBM: ±1500 V (BAT pin), ±2000 V (all other pins); CDM ±500 V
Key Specs:
- Average current, GE low (disabled): 0.05 μA typ
- Average current, ACC mode (update every 30 min): 0.3 μA typ
- Average current, SOH mode (update every 8 h): 0.06 μA typ
- Average current, EOS mode (update every 8 h, 3-s load pulse): 0.35 μA typ
- Active current: ACCU 130 μA, SOH 40 μA, EOS burst 315 μA, EOS gather 75 μA (typ, GE high)
- LDO output (VREG25): 2.5 V typ (2.3–2.7 V) for 2.7 V ≤ VREGIN ≤ 4.5 V, IOUT ≤ 16 mA; short-circuit limit 250 mA max
- Coulomb counter: input range ±0.125 V, 14–15 bit resolution, 1 s conversion, 10 μV typ offset, INL ±0.007% FSR
- Power-on reset threshold: 2.20 V typ (2.05–2.31 V), 115 mV hysteresis
- Internal temperature sensor gain: -2 mV/°C typ
- GE input: VIL max 0.8 V, VIH min 2.65 V (VREGIN = 2.8–4.5 V)
Features:
- Fuel gauge and battery diagnostics that predict end-of-service or early battery failure
- Supports Li-SOCl2 and Li-MnO2 chemistries
- State-of-health (SOH) algorithm for Li-MnO2
- End-of-service (EOS) algorithm for Li-SOCl2
- Coulomb accumulation (ACC) algorithm for all battery types
- Gauge enabled through host-controlled periodic updates via the GE pin
- I²C host communication with configurable ALERT interrupt
- Battery information data logging for diagnostics and failure analysis
- SHA-1 authentication to help prevent counterfeit battery use
- Internal 2.5 V LDO, voltage, current and temperature measurement
Applications:
- Smart meters and flow meters
- Door access control
- Smoke and gas leak detectors
- Building automation
- IoT sensor nodes
- Asset tracking
Package:
- TSSOP-14 (PW), 5.00 mm × 4.40 mm
BQ35100PWR Features
- 1 · Fuel gauge and battery diagnostics for flow meter applications predict end-of-service or early battery failure
- -Supports lithium thionyl chloride (Li-SOCl2) and lithium manganese dioxide (Li-MnO2) chemistry batteries
- -Accurate voltage, temperature, current, and coulomb counter measurements that report battery health and service life
- -State-of-health (SOH) algorithm for Li-MnO2
- -End-of-service (EOS algorithm for Li-SOCl2)
- -Coulomb accumulation (ACC) algorithm for all battery types
- Ultra-low average power consumption to maximize battery run time
- -Gauge enabled through host-controlled periodic updates
- -State-of-health (SOH) ~0.06 μA
- -End-of-service (EOS) ~0.35 μA
- -Coulomb accumulation (ACC) diagnostic updates ~0.3 μA
- System interaction capabilities
- -I 2 C host communication, providing battery parameter and status access
- -Configurable host interrupt
- -Battery information data logging options for in operation diagnostics and failure analysis
- -SHA-1 authentication to help prevent counterfeit battery use
BQ35100PWR Applications
- Used in primary battery systems and suitable for dynamic load and large ambient temperature change applications
- -Smart meters and flow meters
- -Door access control
- -Smoke and gas leak detectors
- -Building automation
- -IoT, including sensor nodes
- -Asset tracking
- Battery status reporting and diagnostics with early failure detection for flow meter systems
- Extends battery runtime with accurate battery gauging for smoke detector, sensor node, and asset tracker applications
1
BQ35100PWR Pin Configuration
BQ35100PWR Absolute Maximum Ratings
Over-operating free-air temperature range (unless otherwise noted) (1)
| MIN | MAX | UNIT | ||
|---|---|---|---|---|
| V REGIN | Regulator Input Range | -0.3 | 5.5 | V |
| V REG25 | Supply Voltage Range | -0.3 | 2.75 | V |
| V IOD | Open-drain I/O pins (SDA, SCL, VEN) | -0.3 | 5.5 | V |
| V IOD | Open-drain I/O pins (ALERT) | -0.3 | 2.75 | V |
| V BAT | BAT Input Pin | -0.3 | 5.5 | V |
| V I | Input voltage range (SRN, SRP, TS) | -0.3 | V REG25 + 0.3 | V |
| T A | Operating free-air temperature range | -40 | 85 | °C |
| T F | Functional Temperature Range | -40 | 100 | °C |
| T STG | Storage temperature range | -65 | 150 | °C |
| T STG | Lead temperature (soldering, 10 s) | -40 | 100 | °C |
BQ35100PWR Recommended Operating Conditions
TA =-40°C to 85°C; Typical Values at TA = 25°C CLDO25 = 1.0 μ F, and VREGIN = 3.6 V (unless otherwise noted)
| MIN | NOM | MAX | UNIT | |||
|---|---|---|---|---|---|---|
| V REGIN | Supply Voltage | No operating restrictions | 2.7 | 4.5 | V | |
| V REGIN | No FLASH writes | 2.45 | 2.7 | V | ||
| C REGIN | External input capacitor for internal LDO between REGIN and V SS | Nominal capacitor values specified. Recommend a 10% ceramic X5R type capacitor located close to the device. | 0.1 | μF | ||
| C LDO25 | External output capacitor for internal LDO between V REG25 | Nominal capacitor values specified. Recommend a 10% ceramic X5R type capacitor located close to the device. | 0.47 | 1 | μF | |
| I CC_GELOW (1) | Gas gauge in Disabled mode | GE = Low | 0.05 | μA | ||
| I CC_ACC_AVE (1) | Gas gauge in ACCUMULATOR mode average current | Update every 30 minutes otherwise GE = Low | 0.3 | μA | ||
| I CC_SOH_AVE (1) | State-of-health average current | Update every 8 hours otherwise GE = Low | 0.06 | μA | ||
| I CC_EOS_AVE (1) | End-of-service average current | Update every 8 hours 3- s Load Pulse otherwise GE = Low | 0.35 | μA | ||
| VA1 | Input voltage range (VIN, TS) | V SS - 0.05 | 1 | V | ||
| VA2 | Input voltage range (BAT) | V SS - 0.125 | 5.0 | V |
BQ35100PWR Thermal Information
| THERMAL METRIC (1) | BQ35100 TSSOP (PW) - 14 PINS | UNIT | |
|---|---|---|---|
| R θ JA, High K | Junction-to-ambient thermal resistance | 103.8 | °C/W |
| R θ JC(top) | Junction-to-case(top) thermal resistance | 31.9 | °C/W |
| R θ JB | Junction-to-board thermal resistance | 46.6 | °C/W |
| ψ JT | Junction-to-top characterization parameter | 2.0 | °C/W |
| ψ JB | Junction-to-board characterization parameter | 45.9 | °C/W |
| R θ JC(bottom) | Junction-to-case(bottom) thermal resistance | N/A | °C/W |
BQ35100PWR Typical Application
The BQ35100 device is a highly configurable device with many options. The major configuration choices comprise the battery chemistry and control methods.
Variants on the same datasheet
These parts have exact links to the same datasheet. They are candidates to compare, not verified drop-in replacements; check package, pinout and electrical limits.
More datasheets
Ask your AI agent about the BQ35100PWR
Connect SheetsData to Claude, Cursor, Codex or any MCP client and your agent reads this datasheet for you: pinout, limits, register maps and design checks, with the numbers taken from the PDF.
claude mcp add --transport http sheetsdata https://mcp.sheetsdata.com/mcp
Then ask: "Can the BQ35100PWR run from my 12 V rail? Check it against the datasheet limits."
Create a free account $2 of usage every month, no card needed.