7448640408
Common Mode Power Line ChokeThe 7448640408 is a common mode power line choke from Würth Elektronik. View the full 7448640408 datasheet below including key specifications.
Manufacturer
Würth Elektronik
Category
Common Mode Power Line Choke
Package
Vertical, 4 PC Pin
Lifecycle
Active
Key Specifications
| Parameter | Value |
|---|---|
| Current Rating (Max) | 1.5A |
| DC Resistance (DCR) (Max) | 120mOhm (Typ) |
| Filter Type | Power Line |
| Height (Max) | 0.886" (22.50mm) |
| Inductance @ Frequency | 1.8 mH @ 10 kHz |
| Mounting Type | Through Hole |
| Number of Lines | 2 |
| Operating Temperature | -40°C ~ 125°C |
| Package / Case | Vertical, 4 PC Pin |
| Packaging | Tray |
| Size / Dimension | 0.835" L x 0.654" W (21.20mm x 16.60mm) |
| Standard Pack Qty | 120 |
| Voltage Rating - AC | 250V |
Overview
Part: 7448640408 — Würth Elektronik eiSos GmbH & Co. KG
Type: Common Mode Power Line Choke
Description: A common mode power line choke with 1.8 mH minimum inductance, 2 A maximum rated current, and a maximum rated voltage of 250 V (AC).
Operating Conditions:
- Operating temperature: -40 up to +125 °C
- Ambient temperature (referring to I R): -40 up to +70 °C
- Storage conditions: < 40 °C ; < 75 % RH
Absolute Maximum Ratings:
- Max rated voltage: 250 V (AC)
- Max continuous current: 2 A (at 70 °C/ ΔT < 55 K)
- Max operating temperature: +125 °C
Key Specs:
- Inductance (min): 1.8 mH (at 10 kHz/ 100 mV)
- Inductance (typ): 2.3 mH (at 10 kHz/ 100 mV)
- Leakage Inductance (typ): 32.7 μH (at 100 kHz/ 100 mV)
- DC Resistance (max): 0.14 Ω (at 20 °C)
- Rated Voltage (max): 250 V (AC) (at 50 Hz)
- Insulation Test Voltage: 2000 V (AC) (at 50 Hz/ 5 mA/ 2 sec.)
- Number of windings: 2
Features:
- RoHS Compliant [2011/65/EU&2015/863]
- REACh Conform or declared [(EC)1907/2006]
- AEC-Q200 Grade 1 Component Qualification
- Moisture Sensitivity Level (MSL) 1
Applications:
- General electronic equipment
Package:
- UT20V
Applications
It has to be clearly pointed out that the possibility of a malfunction of electronic components or failure before the end of the usual lifetime cannot be completely eliminated in the current state of the art, even if the products are operated within the range of the specifications. In certain customer applications requiring a very high level of safety and especially in customer applications in which the malfunction or failure of an electronic component could endanger human life or health it must be ensured by most advanced technological aid of suitable design of the customer application that no injury or damage is caused to third parties in the event of malfunction or failure of an electronic component. Therefore, customer is cautioned to verify that data sheets are current before placing orders. The current data sheets can be downloaded at www.we-online.com.
Package Information
Get structured datasheet data via API